TROUBLESHOOTING
Page 17
PROBLEM
CAUSE
SOLUTION
Control valve fails to
refill brine tank
Improper refill time setting
Verify that refill time corresponds to salt level and
amount of filter media
Plugged refill flow control
Clean refill flow control
Loss of filter media
Lower and/or upper distributor damaged
Replace distributor(s)
Leak between riser tube and upper distributor
Verify that riser tube is seated correctly and is not
cracked
Control valve fails to
draw brine
Low operating pressure
Check operating pressure; must be higher than 1,4
bar
Plugged injector
Clean injector
Restricted drain line
Verify drain line for kinks or restrictions
Restricted brine line
Verify brine line for kinks or restrictions
Leak in brine line
Verify brine line and connections for air leakage
No water in brine tank
Refer to problem “Control valve fails to refill brine
tank”
Control valve cycles
continuously
Defective micro switch
Replace micro switches
Appliance fails to
backwash properly
Low operating pressure
Check operating pressure; must be higher than 1,4
bar
Insufficient water supply
Check water supply (flow rate/dynamic pressure)
Restricted drain line
Verify drain line for kinks or restrictions
Excessive build-up of impurities in pressure tank Clean or replace filter media and control valve;
increase regeneration frequency
Plugged backwash flow control
Clean or replace backwash flow control
Plugged top or bottom distributor
Verify that top and bottom distributor are clean and
slots are not clogged by iron or other impurities
Filter media is completely ‘caked’ (solid block)
Replace filter media and increase regeneration
frequency
Summary of Contents for PF-BTA
Page 15: ...Page 15...
Page 21: ...E Page 21...
Page 22: ...EXPLODED VIEW PF MMX SYSTEM Page 22...
Page 24: ...EXPLODED VIEW PF MMX TIMER ASSEMBLY Page 24...
Page 26: ...EXPLODED VIEW PF MMX VALVE BODY Page 26...
Page 31: ...Page 31...
Page 32: ...erie water treatment a division of Aquion Inc www eriewatertreatment com...