MAINTENANCE 

 

 

 

Page 14 

RECOMMENDATION 

 

Notwithstanding the reliability of the appliance, we strongly 
recommend to have it serviced and maintained on a regular 
basis by a competent and duly trained technician. He will be 
able to determine the appropriate maintenance interval for 
the appliance, depending on your specific application and the 
local  operating  conditions.  The  advantages  of  performing 
regular maintenance are: 

 

regular  check  of  the  local  operating  conditions  (water 
quality, pressure, etc); 

 

regular  control  and  adjustment  of  the  settings  of  the 
appliance,  to  guarantee  it  operates  at  maximum 
efficiency; 

 

minimize the risk of unexpected break-down. 

Contact your dealer or installer for more information, or visit 
our website. 
 

ROUTINE CHECKS 

 
Regularly the user should perform a basic check to verify if the 
appliance  is  functioning  correctly,  on  the  basis  of  the 
following control points: 
1.

 

Check settings of electronic control panel. 

2.

 

Check water composition before/after appliance. 

3.

 

Check  drain  line  from  control  valve;  there  shouldn’t  be 
any water flow (unless appliance is in regeneration).  

4.

 

Check drain line from brine tank overflow; there shouldn’t 
be any water flow. 

5.

 

Check appliance and surrounding area; there shouldn’t be 
any water leakages. 

 

BYPASSING THE APPLIANCE 

 
Occasionally  it  may  be  necessary  to  put  the  appliance 
hydraulically  in  bypass,  i.e.  to  isolate  it  from  the  water 
distribution system; f.e.: 

 

in case of an urgent technical problem; 

 

when  it  is  not  necessary to  supply treated  water  to the 
application. 

 
WITH FACTORY BYPASS (optional)  
 

  

Picture 6.a

 

SERVICE POSITION 

 = inlet valve to appliance is OPEN 

 = outlet valve from appliance is OPEN 

 

  

Picture 6.b

 

BYPASS POSITION 

 = inlet valve to appliance is CLOSED 

 = outlet valve from appliance is CLOSED 

 

  

Picture 6.c

 

MAINTENANCE POSITION 

 = inlet valve to appliance is OPEN 

 = outlet valve from appliance is CLOSED 

 
 
 
 
 

WATER CONDITIONER SALT 

 
This  appliance  needs  'brine'  for  its  periodic  regenerations. 
This brine solution is made from water, that is automatically 
dosed  in  the  brine  tank  by  the  control  valve,  and  water 
conditioner  salt.  The  user  should  make  sure  that  the  brine 
tank is always kept full of water conditioner salt. Therefore he 
should periodically check the salt level inside the brine tank 
and  refill  it  if  necessary.  Simply  lift  the  brine  tank  cover  to 
check the salt level inside the brine tank. 
 
Ideally the level of water conditioner salt inside the brine tank 
is  kept  between  1/3  and  2/3.  A  lower  level  of  water 
conditioner  salt  can  cause  insufficient  brine  saturation, 
resulting in a loss of softening capacity. A higher level of water 
conditioner  salt  can  cause  salt  bridging  (hard  crust  or  salt 
bridges in the brine tank). When you suspect salt bridging: 

 

carefully pound on the outside of the brine tank to break 
loose the salt bridges; 

 

using a broom (or like blunt tool) carefully push the salt to 
break it apart; 

 

pour warm water over the top of the salt to dissolve it. 

 

FILTER MEDIA CLEANER 

 
Other contaminants present in the feed water can cause the 
filter  media  (especially  the  ion  exchange  resin)  to  foul  up, 
resulting  in  a  loss  of  filtration  capacity.  An  approved  filter 
media cleaner  can  be  used  periodically  to thoroughly  clean 
the filter media. 
 

SANITIZING THE APPLIANCE 

 
This  appliance  is  manufactured  from  premium  quality 
material and assembled in safe conditions to assure it is clean 
and sanitary. If installed and serviced correctly, this appliance 
will not infect or contaminate your water supply. However, as 
in any 'device' plumbed-in in your water distribution system, 
a  proliferation  of  bacteria  is  possible,  especially  in  case  of 
'stagnant water'. Therefore this appliance is equipped with a 
'days override' feature, that will automatically rinse the filter 
media periodically, even in case of low or absence of water 
usage. 
 
If  the  power  supply  to  the  appliance  is  disconnected  for  a 
longer  period  of  time,  we  recommend,  when  the  power 
supply  is  re-established,  to  manually  initiate  a  complete 
regeneration. 
 
 

Summary of Contents for PF-BTA

Page 1: ...2019 erie water treatment TM EN PF MMX Rev2019 03 Technical Manual MULTI PURPOSE WATER FILTER Models PF MMX PF BTA...

Page 2: ...ic control panel Page 9 Maintenance Page 13 Troubleshooting Page 14 Electrical wiring diagram Page 16 Default configuration parameter settings Page 17 Composition overview Page 18 Exploded view PF MMX...

Page 3: ...nly be undertaken by a competent person aware of the local codes in force All plumbing and electrical connections must be done in accordance with local codes Before setting up the appliance make sure...

Page 4: ...below the minimum OPERATING TEMPERATURE MIN MAX 2 48 C 35 120 F do not install the appliance in an environment where high ambient temperatures e g unvented boiler house or freezing temperatures can oc...

Page 5: ...ith the optional Wi Fi function indicate this by adding W to the corresponding part number PN 35810 Softener 1 Simplex 25L PN 35810 W Softener 1 Simplex 25L Wi Fi enabled 2400VS J4JB PRL1 Control Valv...

Page 6: ...n 6 Unplug the top of the riser tube CONTROL VALVE 1 Make sure the O ring in the riser insert and the tank O ring around the threaded section of the control valve are in the correct position 2 Screw t...

Page 7: ...ve make sure to install the gasket seals Tighten the nuts firmly by hand 3 Connect the IN valve of the 3 valve connection kit to the adaptor on the in port of the control valve 4 Connect the OUT valve...

Page 8: ...N valve 6 After 2 3 minutes open a cold treated water faucet nearby the appliance and let the water run for a few minutes until all air is purged fromthe installation and the filter media is rinsed it...

Page 9: ...ppen 1 the display will intermittently show the message 2 the buzzer if enabled see Basic Settings will beep 3 times every 5 minutes While the appliance will continue to operate normally it is recomme...

Page 10: ...r down button to activate the holiday mode by setting the number of full days away from home or deactivate the holiday mode OFF Once the control panel is back in service mode the display will show The...

Page 11: ...TIONS CONFIGURATION PARAMETERS Before entering the programming mode make sure that the appliance is in the service mode All configuration parameters on this appliance have been pre programmed in the f...

Page 12: ...ayed regeneration at the programmed time of regeneration is started 10 Press the scroll button again the display will show only when the regeneration mode is set to Delayed or Dlyd Immd Press the up o...

Page 13: ...s number of regenerations since installation TotVol total volume of treated water since installation LastRgn consumed capacity at last regeneration InstFlow instantaneous flow rate through appliance A...

Page 14: ...appliance needs brine for its periodic regenerations This brine solution is made from water that is automatically dosed in the brine tank by the control valve and water conditioner salt The user shou...

Page 15: ...Page 15...

Page 16: ...roblem Excessive water in brine tank Appliance regenerates too frequently Verify program Excessive water in brine tank Control valve fails to draw brine Refer to problem Control valve fails to draw br...

Page 17: ...k in brine line Verify brine line and connections for air leakage No water in brine tank Refer to problem Control valve fails to refill brine tank Control valve cycles continuously Defective micro swi...

Page 18: ...ition switches flow meter power lead drive motor auxilliary contacts 24 VDC max 500mA AUX1 PF SOF1 SIM service valve NO optional PF SOF1 PRL service valve NO PF SOF1 ALT service valve NC AUX2 PN 74372...

Page 19: ...cle 2 BRINE DRAW SLOW RINSE min 57 50 78 88 Cycle 3 FAST RINSE REFILL min 2 4 6 4 6 Regen Dlyd Immd Dlyd Immd Dlyd Immd Dlyd Immd Regen 2 00 2 00 2 00 2 00 Rsrv Variable Variable Variable Variable Aux...

Page 20: ...transformer 1 BSP male connections Pressure tank incl distributor assy Filter media 12 kg bag Ltr model model PF MMX 24 35690 2400VS J4JB PRL1 1 10x35 1 2 36 35691 2400VS J1JB PRL1 1 10x47 1 3 48 356...

Page 21: ...E Page 21...

Page 22: ...EXPLODED VIEW PF MMX SYSTEM Page 22...

Page 23: ...e assembly to be cut to length 20mm below pressure tank opening 4 74312 Transformer 100 230 24 VDC 50Hz 1 0A EuroT plug 74313 Transformer 100 230 24 VDC 50Hz 1 0A UK plug 5 287 166 Top distributor 6 2...

Page 24: ...EXPLODED VIEW PF MMX TIMER ASSEMBLY Page 24...

Page 25: ...15 222 Screw drive motor assembly 2x 12 74267 Cable clamp 13 70312 Strain relief power lead 14 74370 Socket cable assembly InterConnect 24 VDC 15 72261 Drive motor 16 75156 Worm drive shaft 17 70965...

Page 26: ...EXPLODED VIEW PF MMX VALVE BODY Page 26...

Page 27: ...o 21 185 007 6 O ring mixing valve 22 568 406 Mixing valve 23 186 118 O ring sleeve 24 568 407 L Sleeve mixing valve 25 568 385 2 B Refill Flow Control 1 9 ltr min 24 Ltr 36 Ltr 568 385 2 D Refill Flo...

Page 28: ...125 BP 0275 01 Brine platform for simplex BT 0275 6 BW4 072 Brine well 10 cm 72 cm BT 0125 BW4 088 Brine well 10 cm 88 cm BT 0275 7 H4500 48 Air check to be cut to length 8 H4640 32 Float 9 Grommet fl...

Page 29: ...inse water usage per regeneration ltr 202 246 348 522 Max flow to drain ltr min 9 8 9 8 15 1 22 7 Dimensions Model PF MMX Filter media ltr 24 36 48 72 Width mm W 264 264 311 365 Depth mm D 282 282 311...

Page 30: ...s Model PF BTA Volume ltr 125 275 Diameter mm D 540 685 Height mm H 850 975 Height overflow mm H1 660 825 Max salt storage capacity kg 100 200 Model PF BTA Volume ltr 125 275 Hydraulic connection brin...

Page 31: ...Page 31...

Page 32: ...erie water treatment a division of Aquion Inc www eriewatertreatment com...

Reviews: