TROUBLESHOOTING
Page 16
PROBLEM
CAUSE
SOLUTION
Untreated water to
service
Open or defective bypass
Close or replace bypass
Appliance in regeneration
Wait until regeneration finishes or manually
advance regeneration to end
No salt in brine tank
Add salt and initiate regeneration manually
Salt bridging in brine tank
Break salt bridge(s) and initiate regeneration
manually
Change in raw water composition
Measure hardness of incoming untreated water and
adjust programming accordingly
Appliance fails to start a regeneration
Refer to problem “Appliance fails to start a
regeneration”
Valve body and timer out of synchronisation
Synchronize valve body and timer
Control valve fails to draw brine
Refer to problem “Valve fails to draw brine”
Decreasing exchange capacity of filter media
Clean or replace filter media
Loss of filter media
Refer to problem “Loss of filter media ”
Leak at riser tube
Verify that riser tube is seated correctly and is not
cracked
Low levels of
contaminant in treated
water
Bypass not completely closed
Close bypass
Excessive service flow rate
Lower service flow rate
Increase filter capacity by increasing volume of filter
media
Appliance fails to start
a regeneration
Faulty electrical supply
Verify electrical service (fuse, transformer,...)
Defective flow meter
Clean and/or replace flow meter
Defective PCB
Replace PCB
Defective drive motor
Replace drive motor
Appliance uses too
much salt
Excessive water in brine tank
Refer to problem “Excessive water in brine tank”
Appliance regenerates too frequently
Verify program
Excessive water in
brine tank
Control valve fails to draw brine
Refer to problem “Control valve fails to draw brine”
Improper refill time setting
Verify that refill time corresponds to the proper salt
level and amount of filter media
Missing refill flow control
Verify that refill flow control is installed and
properly sized
Leak from control valve to brine tank
PF-SOF1 only: check synchronisation between valve
body and timer
PF-SOF1,5 only: check brine line shut-off valve of
valve body
Salt taste in treated
water
Excessive water in brine tank
Refer to problem “Excessive water in brine tank”
Injector undersized
Verify injector selection and operating pressure
Improper brine/slow rinse time setting
Verify that brine/slow rinse time corresponds to the
proper salt level and amount of filter media
Loss of water pressure
Build-up of impurities in pressure tank
Clean filter media bed and control valve; increase
regeneration frequency
Plugged lower and/or upper distributor
Verify that distributors are free of debris
Drain line from control
valve flows
continuously
Appliance in regeneration
Wait until regeneration finishes or manually
advance regeneration to end
Faulty electrical supply
Verify electrical service (fuse, transformer,...)
Defective drive motor
Replace drive motor
Defective micro switch
Replace micro switches
Defective PCB
Replace PCB
Valve body and timer out of synchronisation
Synchronise valve body and timer
Drain line from brine
tank overflow flows
continuously
Excessive water in brine tank
Refer to problem “Excessive water in brine tank”
Summary of Contents for PF-BTA
Page 15: ...Page 15...
Page 21: ...E Page 21...
Page 22: ...EXPLODED VIEW PF MMX SYSTEM Page 22...
Page 24: ...EXPLODED VIEW PF MMX TIMER ASSEMBLY Page 24...
Page 26: ...EXPLODED VIEW PF MMX VALVE BODY Page 26...
Page 31: ...Page 31...
Page 32: ...erie water treatment a division of Aquion Inc www eriewatertreatment com...