DIAGNOSTICS MODE 

 

 

In  the  Diagnostics  mode several  operating parameters 

can be consulted; particularly during a service intervention, 
these parameters  can be helpful  to identify  the  cause of  a 
problem or malfunction. 

 

 

Before  entering the  Diagnostics  mode,  make sure that 

the appliance is in service mode. 

 

 

In  case  no  button  is  pressed  in  a  period  of  5  min,  the 

control panel will automatically return to the service mode! 
 
Accessing the Diagnostics mode 
1.

 

Press the scroll 

 button and hold it for 6 sec until the 

display shows: 

 
 
 
 
2.

 

Within 10 sec, press the down 

 button; the display will 

show: 

 
 
 
 

 

You are now in the Diagnostics mode.  

 

Press  the  scroll 

  button  to  advance  to  the  next 

diagnostics parameter. 

 
Available diagnostics parameters  

 

Regen  X  days  ago:  number  of  days  since  last 
regeneration. 

 

In Srvc: total number of days in service. 

 

# of Regens: number of regenerations since installation. 

 

TotVol: total volume of treated water since installation.          

 

LastRgn@: consumed capacity at last regeneration. 

 

InstFlow: instantaneous flow rate through appliance.  

 

AvgVol: calculated average daily water usage.  

 

Capacity: calculated capacity between regenerations.  

 

Hardness: setting of water hardness.  

 

Rsrv: setting of reserve capacity. 

 

Regen @: setting of time of regeneration. 

 

Override:  setting  of  number  of  days  between 
regenerations.  

 

Cycle X: setting of length of corresponding regeneration 
cycle. 

 

Units: control is programmed for Metric units.  

 

MTR: setting of the water meter. 

 

Capacity: control is programmed for hardness setting. 

 

Regen: setting of the regeneration mode.  

 

Valve Type: setting of valve type. 

 

MP Resets: number of resets of the microprocessor. 

 

Memory Reset: number of corrupt memory start-ups. 

 

EZRSDg: software version. 

 

CapToUse: remaining capacity. 

 
Exiting the Diagnostics mode 
1.

 

Press  the  scroll 

  button  repeatedly  until  the  display 

shows: 

 
 
 
 

 

Press  the  up 

  or  down 

  button  to  exit  the 

Diagnostics mode. 

 

Regen XXdays ago

 

System Check

 

Exit

 

Summary of Contents for PF-BTA

Page 1: ...2019 erie water treatment TM EN PF MMX Rev2019 03 Technical Manual MULTI PURPOSE WATER FILTER Models PF MMX PF BTA...

Page 2: ...ic control panel Page 9 Maintenance Page 13 Troubleshooting Page 14 Electrical wiring diagram Page 16 Default configuration parameter settings Page 17 Composition overview Page 18 Exploded view PF MMX...

Page 3: ...nly be undertaken by a competent person aware of the local codes in force All plumbing and electrical connections must be done in accordance with local codes Before setting up the appliance make sure...

Page 4: ...below the minimum OPERATING TEMPERATURE MIN MAX 2 48 C 35 120 F do not install the appliance in an environment where high ambient temperatures e g unvented boiler house or freezing temperatures can oc...

Page 5: ...ith the optional Wi Fi function indicate this by adding W to the corresponding part number PN 35810 Softener 1 Simplex 25L PN 35810 W Softener 1 Simplex 25L Wi Fi enabled 2400VS J4JB PRL1 Control Valv...

Page 6: ...n 6 Unplug the top of the riser tube CONTROL VALVE 1 Make sure the O ring in the riser insert and the tank O ring around the threaded section of the control valve are in the correct position 2 Screw t...

Page 7: ...ve make sure to install the gasket seals Tighten the nuts firmly by hand 3 Connect the IN valve of the 3 valve connection kit to the adaptor on the in port of the control valve 4 Connect the OUT valve...

Page 8: ...N valve 6 After 2 3 minutes open a cold treated water faucet nearby the appliance and let the water run for a few minutes until all air is purged fromthe installation and the filter media is rinsed it...

Page 9: ...ppen 1 the display will intermittently show the message 2 the buzzer if enabled see Basic Settings will beep 3 times every 5 minutes While the appliance will continue to operate normally it is recomme...

Page 10: ...r down button to activate the holiday mode by setting the number of full days away from home or deactivate the holiday mode OFF Once the control panel is back in service mode the display will show The...

Page 11: ...TIONS CONFIGURATION PARAMETERS Before entering the programming mode make sure that the appliance is in the service mode All configuration parameters on this appliance have been pre programmed in the f...

Page 12: ...ayed regeneration at the programmed time of regeneration is started 10 Press the scroll button again the display will show only when the regeneration mode is set to Delayed or Dlyd Immd Press the up o...

Page 13: ...s number of regenerations since installation TotVol total volume of treated water since installation LastRgn consumed capacity at last regeneration InstFlow instantaneous flow rate through appliance A...

Page 14: ...appliance needs brine for its periodic regenerations This brine solution is made from water that is automatically dosed in the brine tank by the control valve and water conditioner salt The user shou...

Page 15: ...Page 15...

Page 16: ...roblem Excessive water in brine tank Appliance regenerates too frequently Verify program Excessive water in brine tank Control valve fails to draw brine Refer to problem Control valve fails to draw br...

Page 17: ...k in brine line Verify brine line and connections for air leakage No water in brine tank Refer to problem Control valve fails to refill brine tank Control valve cycles continuously Defective micro swi...

Page 18: ...ition switches flow meter power lead drive motor auxilliary contacts 24 VDC max 500mA AUX1 PF SOF1 SIM service valve NO optional PF SOF1 PRL service valve NO PF SOF1 ALT service valve NC AUX2 PN 74372...

Page 19: ...cle 2 BRINE DRAW SLOW RINSE min 57 50 78 88 Cycle 3 FAST RINSE REFILL min 2 4 6 4 6 Regen Dlyd Immd Dlyd Immd Dlyd Immd Dlyd Immd Regen 2 00 2 00 2 00 2 00 Rsrv Variable Variable Variable Variable Aux...

Page 20: ...transformer 1 BSP male connections Pressure tank incl distributor assy Filter media 12 kg bag Ltr model model PF MMX 24 35690 2400VS J4JB PRL1 1 10x35 1 2 36 35691 2400VS J1JB PRL1 1 10x47 1 3 48 356...

Page 21: ...E Page 21...

Page 22: ...EXPLODED VIEW PF MMX SYSTEM Page 22...

Page 23: ...e assembly to be cut to length 20mm below pressure tank opening 4 74312 Transformer 100 230 24 VDC 50Hz 1 0A EuroT plug 74313 Transformer 100 230 24 VDC 50Hz 1 0A UK plug 5 287 166 Top distributor 6 2...

Page 24: ...EXPLODED VIEW PF MMX TIMER ASSEMBLY Page 24...

Page 25: ...15 222 Screw drive motor assembly 2x 12 74267 Cable clamp 13 70312 Strain relief power lead 14 74370 Socket cable assembly InterConnect 24 VDC 15 72261 Drive motor 16 75156 Worm drive shaft 17 70965...

Page 26: ...EXPLODED VIEW PF MMX VALVE BODY Page 26...

Page 27: ...o 21 185 007 6 O ring mixing valve 22 568 406 Mixing valve 23 186 118 O ring sleeve 24 568 407 L Sleeve mixing valve 25 568 385 2 B Refill Flow Control 1 9 ltr min 24 Ltr 36 Ltr 568 385 2 D Refill Flo...

Page 28: ...125 BP 0275 01 Brine platform for simplex BT 0275 6 BW4 072 Brine well 10 cm 72 cm BT 0125 BW4 088 Brine well 10 cm 88 cm BT 0275 7 H4500 48 Air check to be cut to length 8 H4640 32 Float 9 Grommet fl...

Page 29: ...inse water usage per regeneration ltr 202 246 348 522 Max flow to drain ltr min 9 8 9 8 15 1 22 7 Dimensions Model PF MMX Filter media ltr 24 36 48 72 Width mm W 264 264 311 365 Depth mm D 282 282 311...

Page 30: ...s Model PF BTA Volume ltr 125 275 Diameter mm D 540 685 Height mm H 850 975 Height overflow mm H1 660 825 Max salt storage capacity kg 100 200 Model PF BTA Volume ltr 125 275 Hydraulic connection brin...

Page 31: ...Page 31...

Page 32: ...erie water treatment a division of Aquion Inc www eriewatertreatment com...

Reviews: