Pin
No.
Signal
Name
Condition
Pin Location
1 CD
Carrier Detect *1
2 RD
Receive Data (FP Host)
3 SD
Send Data (FP Host)
4 DTR
Data Terminal Ready *1
5 GND
Ground
6 DSR
Data Set Ready *1
7 RS
Request to Send (FP Host)
8 CS
Clear to Send (FP Host)
9 NC
(Used internally)
→
←
→
←
RS-232C (Serial) Interface Pin Assignments and Signal Names
*1 The FP unit's CD, DTR, and DSR lines are connected internally.
Connector :
Dsub 9 pin female
Connector set screw :
Inch type (4-40)
RS-232C Cable :
FP61V-IS00-O
(Manufactured by Digital Electronics Corporation of Japan)
Signal Names
Signal names used for FP unit RS-232C interfaces are designed to match the pin order used
on most PC serial connectors, which allows a straight cable to be used to connect the two.
Therefore, connect each FP connector pin's signal to the same signal signal on the PC side.
For example, the FP unit connector's pin #2 'RD' should be connected to the PC
connector's 'RD' terminal. Refer to the FP-2500/FP-2600 Series User Manual's "Cable
Diagrams" section for detailed signal direction information.
If a cable other than the specified RS-232C cable is used, FP unit operation
cannot be guaranteed due to the possibility of noise interference.
RS-232C Interface
Baud rate: 9600 bps
Data length: 8 bits
Parity: none
Stop bit: 1
RS-232C Interface
6
9
1