Plot Data Line Format
A plot data line may contain any number of plot data bytes up to the maximum of 132 for horiĆ
zontal dot density of 60 dpi (Data Processing mode) or 198 bytes for a horizontal dot density of
90 dpi (Correspondence mode). If Auto Line Feed is disabled, any bytes over the maximum are
lost. If the maximum is exceeded and Auto Line Feed is enabled, a Line Feed (LF) is forced and
the remaining plot data is printed as text on the next line.
The plot mode control code may occur anywhere in the line prior to the line terminator, but
plot speed may decrease if it is not at the beginning of the line.
NORMAL DENSITY PLOT
For normal density plot, the plot line contains: Control Code 05 hex, plot data bytes, and a Line
Terminator (0A hex or 0C hex). The control sequence for sending the P-Series
Normal DensiĆ
ty Plot
is as follows:
1.
Send the plot command code ENQ (05 hex).
2.
Send the plot data bytes (refer to NO TAG on page NO TAG).
3.
Send a line terminator, either a Line Feed (LF, 0A hex) or a Form Feed (FF, 0C hex). A
Carriage Return (CR) may also be used instead of the LF code, provided the Carriage
Return has been configured for Carriage Return = Carriage Line Feed (CR =
CR + LF).
a.
A line feed (0A hex) used as the line terminator causes the contents of the buffer to
be plotted and the paper advances a
single dot row
, based on the vertical density of
the current mode.
b.
A form feed (0C hex) used as the line terminator causes the contents of the buffer to
be plotted and the paper to advance to the
top of the next form.
4.
Regardless of which line terminator code is sent, the printer will default to the previously
selected print mode unless further plot control codes are provided with the data.
NOTE: Failure to adhere to this format may cause unexpected results.
DOUBLE DENSITY PLOT
For double density plot, the plot line contains: Control Code 04 hex, plot data bytes, a Line
Terminator (0A hex or 0C hex), Control Code 05 hex, plot data bytes, and a Line Terminator.
The control sequence for sending P-Series
Double Density Plot
is as follows:
1.
Send the even dot plot control code EOT (04 hex), followed by plot data bytes (refer to
NO TAG on page NO TAG).
2.
Send a line terminator, which causes the printer to plot the data bytes; the paper is
not
advanced in Double Density Plot; the printer now waits for the second plot command and
plot data bytes.
Summary of Contents for P9000 Series
Page 1: ...P9000 Series Multifunction Printer User s Reference Manual R...
Page 2: ......
Page 3: ...P9000 Series Multifuction Printer User s Reference Manual R P N 133397 001 Rev B...
Page 12: ...P9012 Multinational User s Reference Manual viii...
Page 18: ...Overview 1 6...
Page 26: ...Operation 2 8 Figure 2 2 Loading Paper...
Page 31: ...2 13 Operation Figure 2 5 Paper Tent Installation Figure 2 6 Paper Stacking...
Page 40: ...Operation 2 22...
Page 43: ...3 3 Configuration Figure 3 1 Sample Configuration Printout...
Page 68: ...Configuration 3 28...
Page 182: ...Routine Service Diagnostics 8 4 Figure 8 2 Cleaning the Paper Motion Detector...
Page 200: ...RibbonMinder 9 14...
Page 230: ...Multinational Character Sets 10 30...
Page 234: ...Installation 11 4 Figure 11 2 Shipping Restraint Removal...
Page 238: ...Installation 11 8...
Page 240: ...P9000 Appendices 10 A 2...
Page 306: ...Appendix C 6...
Page 312: ...Appendix D 6...
Page 322: ...Appendix E 10...
Page 326: ...Appendix F 4 Figure F 2 Removing the DCU PCBA...
Page 333: ......