34
Maintenance and Troubleshooting
Section 6: Maintenance and
Troubleshooting
The follow maintenance should be done according to the schedule
below:
Maintenance Action
Frequency
Section
Clean Guide Shafts
Before every
6D
label roll*
Clean Encoder Strip
Every five label
6D
rolls*
Replace Exhaust System Before every
6A
label roll
Clean Print Support Plate Before every smoke 6A (Step 4)
label roll
Clean Exhaust Duct
As needed for
6C
(bottom edges)
smokeless labels
Clean Laser Windows
As needed
6B
(inspect regularly)
* During the break-in period you will see more debris on these
components which may require more frequent cleaning. Over time the
amount of debris will diminish and so will the need to clean these
components.
A. REPLACING THE EXHAUST DUCT AND EXHAUST
CHIMNEY
If smoke labels are used, the Exhaust Duct and Exhaust Chimney will
need periodic replacement.
Replace the exhaust system every time you change to a new roll of
smoke label stock!
You may also need to replace the exhaust system if poor print quality
occurs. If text or graphics are no longer sharp or missing entirely, it is
possible the glass on the Exhaust Duct has become clouded. If duct
replacement is necessary more than once during a single roll, the
filtration system may not be working properly.