Lift Motor Replacement
About
This procedure provides instruction to remove and install the Lift Motor.
Videos
Lubricate the lift motor jackscrew
Specifications
System Component
Specification
Lift Motor Calibration Distance*
9" +/- 1/4" (23 cm +/- 0.6 cm
Ramp Yoke Bolts
330 in-lbs (27.5 ft-lbs or 37.2 Nm)
Note: * Calibration distance is set at incline level 10.
Lift motor power
Lift motor power is supplied by the battery thru the lift motor fuse located on the
LPCA
1
board,
see
"LPCA Fuse Locations" on page 173
. The battery must be in good condition and charged
1
Lower printed circuit assembly; generally this refers to the lower board. On treadmills, this is
the motor controller unit (MCU), and on self-powered units, it is the main board in the lower
section.
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.
Page 161
6 Replacement Procedures
Lift Motor Replacement