ID
Description
Ramp Pivot Cover
Specifications
System Component
Specification
Ramp Hinge Pivot Bolts
1080 in-lbs (90 ft-lbs or 122 Nm)
Procedure
Review entire procedure before starting.
Removal Instructions
This procedure will require a fully charged good battery to operate the lift motor.
IMPORTANT
: It's important to follow the removal steps in sequence to successfully
remove the ramp.
1. Access the service menu diagnostic
CrossRamp Test
and set the incline level to 1.
a. On LED P10, P30, P30i and P31 consoles: (
Service menu (51765761)
>
MACHINE TEST
>
CROSSRAMP TEST
and set the
INCLINE LEVEL
to 1).
b. On P62, P80, and P82 consoles: (
Service menu (51765761)
>
System Set-
tings
>
System Tests
>
CrossRamp Test
and set the
INCLINE
level to 1).
2. Disconnect the Lift Motor input power/control cable connector.
WARNING
: Make sure to disconnect the Lift Motor input power/control cable or it is
possible for the crossramp to automatically lower to level 1 under certain cir-
cumstances, such as, if the CrossRamp Test is exited or the console powers down.
This unexpected action could cause personal injury.
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.
Page 96
6 Replacement Procedures
Covers and Panels Replacement