12
To install moving arms:
1. Insert the shaft of the moving arm to the center mount and align pre-installed set
screws
to the shaft (see Figure 12). Fully tighten all screws, including pre-
installed ones (torque = 300 in-lbs, 34 N-m).
Figure 12
2. Attach the link to the moving arm using the 9/16-inch socket wrench
on the pre-installed bolts.
Note
Make sure to place the inner cover
between parts before bolting the
components together.
3. Attach the outer link covers
using two Plastite screws
(torque for 4= 20
in-lbs, 3.4 N-m.).
To install fixed arms:
1. Install the console. For instructions, refer to the console guide included in
the console box.
2. Install two Plastite screws
into the upper display (see Figure 13).
3. Insert the shaft of the arm to the center mount using two set screws
.
Partially tighten mounting fasteners.
4. Rotate arm assembly up and attach clamp using two self-tapping screws
.
5. Fully tighten all fasteners (torque for 2 and 3 = 300 in-lbs, 34 N-m and
torque for 4 =20 in-lbs, 3.4 N-m).