Maintenance of the Compressor
21
To empty the vessel for condensate do as follows:
Remove the container (2) by light moving clockwise
from the bottom of the vessel for condensate.
Drain condensate from the container (2) accordingly
to working legislative directions in the place of use.
Place the container (2) by light moving
counterclockwise onto the bottom of the vessel for
condensate.
Blowing Safety Valve of Maximal Pressure
One should check the blowing safety valve of maximal pressure regularly. For that, it is necessary blowing
the safety valve.
Switch on the compressor by pressing the start
button.
Turn the channelled screw joint for the air (1) up
towards to the safety valve (2) clockwise until the
safety valve is blown.
Switch off the compressor.
Blow the compressor manually.
Turn the channelled screw joint for the air (1)
counterclockwise outside.
Cleaning the Case and External Surfaces
LOOK OUT!
It is possible breakdown of the compressor because of unsuitable cleansers.
For cleaning use a duster that is only dry, lightly wet or moistened in a weak soap solution.
Light Pollution
Rub over the case of the compressor by a dry duster.
Lubricate all metallic parts of the compressor by a thin coat of the special oil of PREBENA.
Strong Pollution
Rub over the case of the compressor by a duster moistened in a weak soap solution.
In conclusion, rub over the case by a duster moistened in running water.
Neatly rub over the case by a dry and soft duster.
Lubricate all metallic parts of the compressor by a by a thin coat of the special oil of PREBENA.
Cleaning Air Filter
Effective cleaning of the being sucked environmental air is one in the most important conditions of long work
of the computer.