Preparation of the Compressor for Work
14
By that check elements as follows:
Does the manometer show increasing filling pressure (5)?
Is the compressor switched off by reaching the maximal pressure automatically (see the specification
beginning from page. 8)?
The maximal filling pressure being produced by the compressor is restricted by the pressure relay
automatically.
WARNING
There is a danger of explosion by excess of the maximum allowable working
pressure.
In no circumstances do anything with the safety valve.
When the pressure is released, the compressor will switch off by reaching the maximal pressure.
(See the specification beginning from p. 8), after that, the device will be blown automatically. The
compressor is ready to work.
Drain condensate as it is written in p. 20.
LOOK OUT!
Condensate is a dangerous substance for the environment.
Bind the spilled condensate by a binder.
Gather the bound condensate by a duster.
Recycle the duster accordingly to working legislative directions in the place of use.
Controlling the Compressor
To control the compressor do as follows:
№
Explication
1
Start button
2
Stop button
3
Counter of working
4
Protection of the electric motor (reset)
5
Manometer for measuring filling pressure
6
Filling valves (take-up cartridges)
Prepare the compressor as it is written below beginning from p. 12.
Check state of cartridges before every switching on.
Observe the operating manual for cartridges of the compressed air.