ITX 3000/2000 Printer User Manual
(UMITX315.PDF
)
Page 44 of 82 Date: 4/27/05
10.4
EEPROM Menu #2 Printout
STORED FORM SIZE
5.50
*MODE
AUTO WITH BU
*SIZE 10s
0
*SIZE 1s
5
CHANGE SIZE
*SIZE 0.1s
5
*SIZE 0.01s
0
*STATUS POINTER
SHORT
*INTERFACE MISC
NORMAL
*PURGE SPOOLER
DISABLED
*PNP RESPONSE
ENABLED
*CONFIG OPTION
STANDARD
10.4.1
EEPROM Menu #2 Parameters
10.4.1.1 Change Stored Size: Forms Len 10's, 1's, 0.1's; 0.01's
Each one of these menu lines causes an incremental change to one of the four digits of the Form Stored Size. Incrementing past
9 returns the digit to 0. Refer to section 9.4.1.2.3.1 for additional information.
10.4.1.2 Form Stored Size
(Display) This data is changed, by the above menu lines or can be automatically loaded using the document's measured size.
Refer to section 9.4 for additional information.
10.4.1.3 Form Mode
The selections for this parameter are "USE STORED FIXED SIZE", "AUTOSIZE WITH BU ENABLED", "AUTOSIZE NO
BU ENABLED". Refer to section 9.4.1.2.3 for additional information.
10.4.1.4 Status Pointer
The selections for this parameter are: "SHORT", "NORMAL", "EXTENDED" , "COMPLETE". Reference the Programmers
Guide
for additional information. This parameter determines the status returned to the host if no alternate selection is made, by a
command, sent over the data interface.
10.4.1.5 Interface Misc.
The selections for this parameter are: “NORMAL” and “ACK 0.5US”. NORMAL does not exercise the ACK signal on the
parallel port. The other selection transmits a 0.5 uSec ACK pulse for those systems that require it.
10.4.1.6 Purge Spooler Control
The selections for this parameter are: “ENABLED” or “DISABLED”. This parameter effects how the printer interface handles
the unsent data after an error occurred during the printing of a document. The default value is “DISABLED” for FGL, and
“ENABLED” for ‘G’. These are different because of the different data modes.
10.4.1.7 Plug and Play (PNP) Response (FGL Only)
For some applications that communicate directly with the printer, the Windows Plug and Play process is a nuisance. Setting
this to “DISABLED” will prevent Windows from reporting “New Hardware Found” on every power up. For all situations that
require a Windows driver and/or Language Monitor, leave this setting to “ENABLED”.
10.4.1.8 Configuration Option
Certain customers have requested unique settings or actions. This setting will report a unique code for those customers. This is
usually set at the factory and should not be changed. This can be changed using this menu, allowing customers with different
installation requirements to reconfigure the printer.