Service center of POWTRAN technology company
My future ,drive and control
CODE
Description of Code
Range of setting
Refer.
value
F0.00
Control mode
0:Vector control mode
0
F0.11
command source selection
1:Terminal command channel (LED ON)
1
F0.03
frequency setting source selection
4:Multiple speed setting
4
F0.13
acceleration time
0.1
~
3600.0s
10
F0.14
deceleration time
0.1
~
3600.0s
10
F1.00
DI1 function selection
1.Forward running direction
1
F1.01
DI2 function selection
2:Reverse rotation (REV)
2
F1.02
DI3 function selection
12:MS speed terminal 1
12
F1.03
DI4 function selection
13:MS speed terminal 2
13
F1.04
DI5 function selection
14:MS speed terminal 3
14
F2.04
SPA collector output selection
4:Frequency level detection FDT output
4
F3.00
Startup mode
1:star up before apply DC braking
2
F3.05
DC brake current at start
0.0
~
100%
60%
F3.04
DC brake keep time
0.0
~
50.s
1.0s
F3.03
DC brake beginning frequency at stop
0.00
~
F01.07
4Hz
F3.06
Dc brake time
0.0
~
50.s
1s
E1.01
MS speed 1
-100.0
~
100.0%
10
E1.02
MS speed 2
-100.0
~
100.0%
50
E1.04
MS speed 4
-100.0
~
100.0%
100
Parameters setting table :