Service center of POWTRAN technology company
My future ,drive and control
15.Frequency UP and Down controlled by
I/O interface terminal board
Control panel
CODE
Description
Range of setting
Refer. value
F0.11
command source selection
1:Terminal command channel (LED ON)
1
F1.10
Teminal command mode
Three-wire type 1
2
F1.00
DI1 function selection
Forward rotation
1
F1.01
DI2 function selection
Reverse rotation
2
F1.02
DI3 function selection
Three-wire operation control
3
F1.03
DI4 function selection
9:frequency UP by terminal (UF)
6
F1.04
DI5 function selection
10:frequency Down by terminal (DN)
7
F1.11
change rate of terminal up and down
0.01
~
100.00Hz/s
1.0Hz
Pa
ram
e
te
rs
s
e
ttin
g
Speed up
Speed up
DI1
DI2
DI3
DI4