Chapter 5 Function parameter
79
Ch
ap
ter 5
The 4 groups of deceleration time are defined exactly the same , please refer to the
instructions of F0.13 and F0.14 . The 4 groups of deceleration time can be switched through
defferent combinations of the multi-function digital input terminal DI, please refer to the
instructions of function code F1.00 to F1.07 in the attachment 2 for the detailed application
methods.
F7.14
Switching frequency point between
acceleration time 1 and acceleration time 2
0.00Hz
~
F0.19
(Maximum frequency)
0.00Hz
☆
F7.15
Switching frequency point between
deceleration time 1 and deceleration time 2
0.00Hz ~ F0.19
(Maximum
frequency )
0.00Hz
☆
The function is active when motor 1 is selected and DI teminal is not selected to switch
between ac/deceleration .it is used to automatically select ac/deceleration time by not DI
terminal but the operating frequency range when the inverter is running.
Output Frequency
(
Hz
)
Set frequency
(
Hz
)
F7.15
F7.14
Acceleration
time 2
Deceleration
time 1
Time(t)
Acceleration
time 1
Deceleration
time 2
Figure 5-19:Schematic diagram of switching between acceleration and deceleration
For the above figure in the process of acceleration, if the operating frequency is less than
F7.14, select acceleration time 1; otherwise select acceleration time 2.
For the above figure in the process of deceleration , if the operating frequency is more than
F7.15, select deceleration time 2; otherwise select deceleration time 2.
F7.16 Forward/reverse rotation deadband
0.00s
~
3600.0s
0.0s
☆
It is the waiting time that the inverter reaches zero speed when the parameter is used to
switch between forward and reverse rotation.
Output frequency
Hz
Time(
t)
Forward
Deadband
Reverse
Figure 5-20:Schematic diagram of the deadband of forward and reverse
F7.17 Reverse rotation control
Allow
0
0
☆
Prohibit
1
For certain production equipments, the reverse rotation may result in damage to the
equipment, the function can disable the reverse rotation. The factory default allows reverse
rotation.
F7.18
Set frequency lower than
lower limit frequency
mode
Running at lower limit frequency
0
0
☆
Stop
1
Zero speed running
2