Chapter 5 Function parameter
25
Ch
ap
ter 5
master setting
37
F0.04
Frequency source
auxiliary setting
0 to 9
2
★
38
F0.05
Reference object
selection for frequency
source auxiliary setting
0. Relative to maximum frequency
1.Relative to master frequency source
A
0
☆
39
F0.06
Frequency source
auxiliary setting range
0% to 150%
100%
☆
40
F0.07
Frequency source
superimposed selection
Units digit: frequency source
selection
Tens digit: Arithmetic relationship of
master and auxiliary for frequency
source
00
☆
41
F0.08
Frequency source offset
frequency when
superimposing
0.00Hz to F0.19(Maximum
frequency)
0.00Hz
☆
42
F0.09
Shutdown memory
selection for digital set
frequency
0: W/O memory
1: W/ memory
1
☆
43
F0.10
Frequency command UP
/ DOWN reference
when running
0: Running frequency
1: Set frequency
0
★
44
F0.11
Command source
selection
0.Keyboard control (LED off)
1.Terminal block control (LED on)
2.Communications command control
(LED flashes)
3. Keyboard
Communications command control
4. Keyboard
Communications command
Terminal block control
0
☆
45
F0.12
Binding frequency
source for command
source
Units digit: binding frequency source
selection for operation panel
command
Tens digit: Terminal command
binding frequency source selection (0
to 9, same as units digit)
Hundreds digit: Communication
command binding frequency source
selection (0 to 9, same as units digit)
000
☆
46
F0.13 Acceleration time 1
0.00s to 6500s
Depends
on models
☆
47
F0.14 Deceleration time 1
0.00s to 6500s
Depends
on models
☆
48
F0.15
Ac/Deceleration time
unit
0:1 second; 1:0.1 second
2:0.01 second
1
★