Chapter 5 Function parameter
107
Ch
ap
ter 5
y1.24
Current of the first fault
The current before the previous fault
●
y1.25
Bus voltage of the first fault
The bus voltage before the previous fault
●
y1.26
Input terminal status of the
first fault
The digital input terminal status before the
previous fault , the order is:
BIT0
BIT1
BIT2
BIT3
BIT4
BIT5
BIT7
DI1
DI2
DI3
DI4
DI5
DI6
DI7
When the input terminal is ON, the
corresponding binary bits is 1, OFF is 0, all
DI status are converted to the decimal
number for display.
●
y1.27
Output terminal status of the
first fault
Output terminal status of the first (at last)
fault
BIT0
BIT1
BIT2
BIT3
Relay
Reserve
SPA
Reserve
When the output terminal ON its
corresponding secondary system is 1, OFF to
0, all DI state into decimal number display
●
y1.29
Power-on time of the first
fault
The current power-on time before the
previous fault
●
y1.30
Running time of the first fault
The current running time before the previous
fault
●