61
MODEL
100KL
120KL
160KL
200KL
BATTERY
Type
Depending on applications
Numbers
32 36 40 (adjustable)
Maximum charging current*
24A**
32A**
40A**
48A**
Floating Voltage
2.29V/cell
Boost Charging
2.35V/cell
Charger Voltage Regulation
< 1%
Ripple Voltage
< 1%
Ripple Current (% C10)
< 5
PHYSICAL
Dimension D X W X H mm
945 x 567 x 1015
995 x 567 x 1455
Single input
Model
Net Weight(kg)
194
229
301
335
Dual Input
Model
Net Weight(kg)
197
232
309
343
ENVIRONMENT
Operation Temperature
0 ~ 40°C
Operation Humidity
<95 % and non-condensing
Operation Altitude***
<1000m**
Acoustic Noise Level
Less than 70dB @ 1 Meter
Less than 73dB @ 1 Meter
MANAGEMENT
Smart RS-232 or USB
Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux, Unix, and MAC
Optional SNMP
Power management from SNMP manager and web browser
*NOTE 1:AC Input >200Vac
**NOTE 2:Scale=1A
***If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be de-rated 1% per 100m.