background image

*

25 HP Subaru OHV engine

*

Cast-iron cylinder sleeve

*

Low oil sensor

*

Receptacles on control panel

*

Electric Start

*

Idle control

*

CordKeeper™

*

8 gallon plastic fuel tank

*

Spark arrester 

*

Portability Kit

A. 120 Volt GFCI Receptacle

Ground Fault Circuit Interrupter duplex receptacle is rated

so that a total of 20 amps may be drawn regardless of whether
both halves or just one receptacle is used.  This receptacle may
be used along with other receptacles provided the generator is
not overloaded and total power drawn is kept within nameplate
ratings.

Ground Fault Circuit Interrupter

(Conforms to U.L 943, Class A and NEC requirements)

This device protects you against hazardous electrical

shock that may be caused if your body becomes a path through
which electricity travels to reach ground.  This could happen
when you touch an appliance or cord that is “ live “ through
faulty mechanism, damp or worn insulation, etc.

The GFCI receptacle cannot be reset once tripped, unless

the generator is running and power is available to it.  Test
regularly to assure proper operation.

B. 120 Volt, 30 Ampere Twistlock Receptacle

You may draw a maximum of 30 amps from this

receptacle.  If other receptacles are used at the same time,
total power used must be kept within nameplate ratings.

C. 120/240 Volt Heavy Duty Receptacle

This receptacle is rated at 50 amps but the current must be 

limited to the nameplate rating.  If this receptacle is used along
with the 120 volt receptacles, the total load drawn must not
exceed the nameplate ratings.

D. Circuit Breakers

The receptacles are protected by an AC circuit breaker.  If

the generator is overloaded or an external short circuit occurs,
the circuit breaker will trip.  If this occurs, disconnect all
electrical loads and try to determine the cause of the problem
before attempting to use the generator again. If overloading
causes the circuit breaker to trip, reduce the load. 

NOTE:

Continuous tripping of the circuit breaker may cause
damage to generator or equipment.  

The circuit breaker may

be reset by pushing the button of the breaker.

E. Idle Control Switch

The Idle Control circuit is designed to extend engine life

and improve fuel usage by slowing the engine down to
approximately 2000 RPM in a “No Load” condition. The noise is
also greatly reduced during this condition.

When power is required from the generator an electronic

control module automatically senses current flow in the
electrical outlet and allows the engine to return to full speed or
standard operating condition. Likewise, when the load is
removed, the generator will automatically return to the idle
condition after a 4-5 second delay.

A convenient switch is mounted in the control panel for

easy access and will disable the Idle Control circuitry when in
the off position.

NOTE:  A 12V battery must be installed in order for the

idle control to function.

F.

CordKeeper™ Restraint

The CordKeeper™ restraint is a unique

feature used to prevent plugs from being
pulled out of the receptacles.

Refer to the appropriate diagram for proper connection of

power cord wires to the plug terminals.

CAUTION:  Insure that the power cord used is 
well insulated and has a sufficient rating to 
match that of the plug.

2

English

CONTROL PANEL

MAJOR GENERATOR FEATURES

POWER CORD CONNECTIONS

120 Volt 30 Amp Plug

120/240 Volt Heavy Duty Plug

Summary of Contents for PM0601350

Page 1: ...cal power when utility power is not available We hope you will enjoy your new generator Welcome to our worldwide family of Coleman Powermate generator users Merci d avoir choisi le groupe lectrog ne C...

Page 2: ...rotected by an AC circuit breaker If the generator is overloaded or an external short circuit occurs the circuit breaker will trip If this occurs disconnect all electrical loads and try to determine t...

Page 3: ...to recharge weak batteries not to boost start vehicles Do not overcharge battery or leave battery unattended CAUTION Do not continue to charge a battery that becomes hot or is fully charged Powermate...

Page 4: ...ier tubing and the side of the wheel If it is less then 1 2 from the carrier turn the wheel over and reinstall Align the wheels parallel to the carrier tubing and tighten nuts securly To align correct...

Page 5: ...uthorization Warranty Period Two 2 years from the date of purchase on products used solely for consumer applications if a product is used for business or commercial applications the warranty period wi...

Page 6: ...e doit pas d passer les valeurs de plaque signal tique D Disjoncteurs Les prises sont prot g es par un disjoncteur alternatif En cas de surcharge ou de court circuit ext rieur le disjoncteur saute Si...

Page 7: ...exc s ou de la laisser sans surveillance ATTENTION Ne pas continuer de charger une batterie chaude ou pleinement charg e Powermate Corporation recommande une batterie de 12 V fournissant au moins 235...

Page 8: ...u tuyau porteur et serrer les crous fond Pour obtenir un bon alignement desserrer les boulons qui fixent la ferrure de roue 6 l aide d un marteau ajouter un chapeau de plastique article 69 l extr mit...

Page 9: ...ts utilis s uniquement pour les applications de consommateur Si le produit est utilis des fins d affaires ou commerciales la p riode couverte par la garantie se limite un 1 an partir de la date d acha...

Page 10: ...no debe exceder las especificaciones de la placa de identificaci n D Interruptor Los recept culos se protegen mediante un cortacircuitos de CA Si se sobrecarga el generador u ocurre un cortocircuito...

Page 11: ...o deje la bater a sin atenci n PRECAUCION No contin e cargando una bater a que se ha quedado caliente o que est completamente cargada Powermate Corporation recomienda una bater a de 12 V con por lo me...

Page 12: ...cas Para alinear correctamente tal vez sea necesario aflojar los pernos que sujetan la m nsula de la rueda 6 Con un martillo coloque el tap n de pl stico art culo 69 en el extremo del eje 7 Repita las...

Page 13: ...pra en productos utilizados nicamente para aplicaciones de consumo si un producto se utiliza para usos comerciales o con fines de lucro el per odo de garant a se limitar a un 1 a o a partir de la fech...

Page 14: ...14 PARTS DRAWING SCHEMA DES PI CES DIAGRAMA DE PIEZAS PM0601350...

Page 15: ...Note B Bolt HH 5 16 18 x 1 5 Boulon Perno 12 27 0048736 Nut Nyloc 5 16 18 crous nyloc Tuerca nyloc 10 28 0000919 01 Bolt whz 3 8 16 X 3 4 Boulon whz Perno whz 5 29 Note B Washer flat 5 16 Rondelles pl...

Page 16: ...late rating of the generator Remarque A Powermate Corporation ne fournit pas de moteurs dans ses pi ces d tach es Les moteurs sont couverts par la garantie du fabricant de moteurs Consulter le manuel...

Page 17: ...tank fuel lines or carburetor sticky valves or corrosion and rust of engine parts 3 Repair required due to overheating Most often caused by overloaded or clogged or damaged or missing flywheel fan inl...

Page 18: ...18 NOTES REMARQUES NOTAS...

Page 19: ...19 NOTES REMARQUES NOTAS...

Page 20: ...of Powermate Corporation 2007 Powermate Corporation Tous droits r serv s sont des marques d pos es de The Coleman Company Inc utilis es sous licence Powermate est une marque d pos e de Powermate Corpo...

Reviews: