28
4111-0044 — June 2021
© 2021 Systems, LLC
A— Lip Hinge Area
B— Platform Hinge Area
C— Upper Hoist Cylinder Pin
D— Cam Rollers (Bearings)
E — Lip Cylinder Pins
F— Side Shift Cylinder Pins
G— Lower Hoist Cylinder Pin
To ensure normal operation of the dock leveler, use
only aircraft hydraulic fluid designed to meet or exceed
military specification MIL-H-5606-G. It is recommended
that the following hydraulic fluids be used:
• ULTRA-VIS-HVI-15
• Aero Shell Fluid 4 or Fluid 41
• Mobil Aero HFA Mil-H5606A or Aero HF
• Texaco Aircraft Hydraulic Oil 15 or 5606
• Exxon Univis J13
• Castrol Brayco Micronic 756
These fluid brands can be mixed together. Use of
hydraulic fluids with equivalent specifications to those
listed here are acceptable.
Use of fluids that do not have equivalent specifications
to those in the preceding list will result in abnormal
operation of the dock leveler and voiding of warranty.
Periodic Maintenance
MAINTENANCE
Weekly Maintenance
• Operate the dock leveler through the complete
operating cycle to maintain lubrication. Verify lip
operates up and down.
• Lock out and tag out the dock leveler, then place
the maintenance props in their service/down
position with hardware tightened by wrench.
• Remove any debris or foreign objects from the lip
hinge and rear hinge areas.
• Inspect warning decals and placards. Replace if
damaged or missing. Reference page 4 for decal
placement.
TOLERANCES
(UNLESS OTHERWISE NOTED)
FRACTIONAL:
1/32"
DECIMAL:
.00 =
.01"
.000 =
.005"
ANGULAR:
1
MATERIAL
DRAWN BY
CHECKED BY
DRAWING NO.
DATE
MarkS
9/23/2020
170381-ZD0
Side Shift RCR
FINAL ASSEMBLY, RAIL RAMP
P O W E R A M P
M C G U I R E
D L M
S Y S T E M S
L o a d i n g D o c k E q u i p m e n t
This print is the property of Systems, LLC and represents a proprietary article in which Systems, LLC retains any and all
patent and other rights, including exclusive rights of use and/or manufacture and/or sale. Possession of this print does
not convey any permission to reproduce, print or manufacture the article or articles shown therein, such permission to be
granted only by written authorization signed by an officer or other authorized agent of Systems, LLC thereof.
STOCK NO.
EASTERDAY FARMS, 50K
REV A - ECN 18-066
A
C
E
F
D
Figure 29
F
C
G
G
B
Summary of Contents for RCR Series
Page 25: ...23 4111 0044 June 2021 2021 Systems LLC OPERATION This page intentionally left blank ...
Page 38: ...36 4111 0044 June 2021 2021 Systems LLC PARTS Platform Hydraulic Hoses C A G F E D B H ...
Page 58: ...56 4111 0044 June 2021 2021 Systems LLC This page intentionally left blank MISCELLANEOUS ...