Mounting and Wiring
9
. Plug the DC cables into the corresponding
inputs on the MICRO inverters and install
the photovoltaic modules.
The recommended installation entails keeping the MICRO inverters
underneath the photovoltaic modules, having them operate in the shade.
Direct sunlight could cause elevated temperatures and consequently derating.
Each module must be connected to the MICRO-Inverter with a DC cable having
a length of less than 3m.
10
. The inverter will not begin to feed energy into the
distribution grid until the association procedure of the
CDD (Concentrator Data Device) has been completed.
See the AURORA CDD Instruction Manual for the
procedures.