POWER ELECTRONICS
PROFIPOWER
TRIAL RUN
39
4.3.4.
Profipower SD700 Type 2 Module
For this module it can be defined up to 20 Scenarios, 10 for the write
command and the other 10 for the read command. This module is
specific for the SD700 drive, and it will operate in the same way that
the module described previously. The gateway will be set up with the
valid Modbus address for the SD700. User only must to select the
available Modbus registers.
The defined frames for this module are: 120 bytes of Data-Output
and 120 bytes of Data-Input.
Therefore, the maximum number of selected Modbus registers will
be 60 for the writing Scenarios and 60 for the reading Scenarios.
That is, all the registers selected for the configured writing Scenarios
do not exceed 60. And in the same way, all the registers selected for
the configured reading Scenarios do not exceed 60.
The description of the Profibus frame will be determined by the
realized set up of the scenarios.
And also the parameters related to the Modbus communication that
had been indicated for the generic module type 1 can be configured.