POWER ELECTRONICS
PROFIPOWER
TRIAL RUN
37
And also the parameters related to the Modbus communication that
have been indicated for the generic module type 1 can be
configured.
4.3.3.
Profipower SD700 Type 1 Module
For this module it can be defined up to 10 Scenarios, 5 for the write
command and the other 5 for the read command. This module is
specific for the SD700 drive, therefore, the gateway will be set up
with the valid Modbus address for the SD700. User only must select
the available Modbus registers.
The defined frames for this module are: 10 bytes of Data-Output and
10 bytes of Data-Input.
Therefore, the maximum number of selected Modbus registers will
be 5 for the writing Scenarios and 5 for the reading Scenarios. That
is, all the registers selected for the configured writing Scenarios do
not exceed 5. And in the same way, all the registers selected for the
configured reading Scenarios do not exceed 5.
The description of the Profibus frame will be determined by the
realized set up of the scenarios.
And also the parameters related to the Modbus communication that
had been indicated for the generic module type 1 can be configured.
The following figure shows an example of Scenarios set up for the
Profipower SD700 Type 1 Module.
Summary of Contents for Profipower
Page 1: ...PROFIPOWER PROFIBUS GATEWAY Communication Network profibus gateway...
Page 2: ......
Page 3: ...modbus profibus gateway Communication Network Edition June 2007 GBC02CI Rev C...
Page 4: ...PROFIPOWER POWER ELECTRONICS 2...
Page 6: ...PROFIPOWER POWER ELECTRONICS 4...
Page 8: ...PROFIPOWER POWER ELECTRONICS 6 INDEX...
Page 49: ...POWER ELECTRONICS PROFIPOWER DIAGNOSIS 47...
Page 51: ...www power electronics com...