PosiPin 7
SECTION [002] DOOR LOCK CONTROL
The Door Lock Control determines the length of time the locking device
remains unlatched after an Access Granted. When
[0]
is programmed, the
lock is unlatched after an Access Granted and remains unlatched until it
receives a second Access Granted (functions like a key). When
[1]
to
[5]
is
programmed, the lock remains unlatched for the defined time period.
Option [2] by default.
SECTION [003] ACCESS GRANTED OPTIONS
The Access Granted Options depend on the Card/Code Options set in
section [001]. Option [0] by default.
Single Access Granted
When
[0]
is programmed, one user can obtain Access Granted by using a
valid card, code or both depending on the Card/Code Option set.
Enter Description
[0]
Card/Code Controlled Free Access (Latched)
[1]
1 second
[2]
5 seconds
[3]
10 seconds
[4]
20 seconds
[5]
60 seconds
Enter Description
[0]
Single Access Granted
[1]
Dual Access Granted
[2]
Dual Access Granted with Dual Panic Disarm