PosiPin 9
SECTION [005] KEYPAD LOCKOUT
When Keypad Lockout is enabled and the Installer Code is entered
incorrectly 3 consecutive times, the keypad ignores all entries for 60
seconds. Option [0] by default.
SECTION [101] BUZZER SETTING
The number of beep tones emitted as a response to a card being presented
to the reader can be adjusted from 0 (disabled) to 7 (7 rapid beep tones).
Option [3] by default.
SECTION [102] FACE LIGHT INTENSITY
The Face Light’s illumination can be adjusted according to the installation’s
requirements from 0 (extinguished) to 8 (brightest). Option [4] by default.
SECTION [103] FACE LIGHT OPERATION
The Face Light can be set to remain illuminated continually or can follow
the state of the Status LEDs. Option [1] by default.
Enter Description
[0]
Keypad Lockout disabled
[1]
Keypad Lockout enabled
Enter Description
[0]
Face Light constant
[1]
Face Light follows Status LEDs