Page 12
Servicing
Lubrication of Right-angle Drive
Use EP oils with SAE 90 viscosity.
The first oil change should take place
after 100 operating hours followed by
further changes after every 1500 operat-
ing hours or once yearly.
Caution!
Used oil must be disposed off
according to environmental regulations.
Check applicable environmental regula-
tions.
Fig. 13 -
Right-angle drive
▼
Total oil capacity of right-angle gear:
•
0.35 l
▼
The maximum constant operating
temperature is 80
°
C.
Type
Type
MP 85-W90
TransGearX-18
Table 5: Suitable hydraulic oils
Oil level and
oil level drain plug
Additional maintenance
information
▼
In case of excessive wear, the wooden
strips of the saw blade guide should be
replaced.
▼
Dismantle the saw blade guard peri-
odically and remove any residues.
▼
Check the operation of the table
return spring.
V-belt Change and
Tensioning
Caution!
Disconnect power supply
before tensioning or changing V-belts.
Fig. 14 - V-belt change and tensioning
1.
Dismantle the circular saw blade.
2.
Loosen the V-belts
Tensioning bolt
Metal flange bearing
Circular saw shaft unit