01H, 17H, 2DH.in decimal: 1, 23, 45] as 3 byte.
Special character data: (FNC 1, CODE A, CODE B)
It is specified “{+ character code" as 2 byte. (It is described separately.)
■ Special characters are defined by combining two characters "{ + an alphanumeric
character." The ASCII character "{" is defined by transmitting "{" twice consecutively.
Specific character
Transmit data
ASCII
Hex
Decimal
SHIFT
{S
7B, 53
123, 83
CODE A
{A
7B, 41
123, 65
CODE B
{B
7B, 42
123, 66
CODE C
{C
7B, 43
123, 67
FNC1
{1
7B, 31
123, 49
FNC2
{2
7B, 32
123, 50
FNC3
{3
7B, 33
123, 51
FNC4
{4
7B, 34
123, 52
{
{{
7B, 7B
123, 123
■ Check digit (1 character) is calculated and added automatically.
■ Special character HRI is processed as follows:
• The printer does not print HRI characters that correspond to the shift character or
code set selection character (CODE A, CODE B, or CODE C).
• HRI characters of the function characters (FNC1, FNC2, FNC3, or FNC4) and control
characters (00H to 1FH and 7FH) are printed as spaces.