- 52 -
Rev. 1.50
A10plus MiniPrinter
CONFIDENTIAL
ESC p
[Name]
Generate pulse
[Format]
ASCII
ESC p
m
t1
t2
Hex
1B
70
m
t1
t2
Decimal
27
112
m
t1
t2
[Range]
m
= 0, 1, 48, 49
0
≤
t1
≤ 255
0
≤
t2
≤ 255
[Description]
Outputs the pulse specified by
t1
and
t2
to the specified connector pin
m
as follows:
m
Connector pin
0, 48
Drawer kick-out connector pin 2
1, 49 Drawer kick-out connector pin 5
• The pulse for ON time is (
t1
× 2 msec) and for OFF time is (
t2
× 2 msec).
[Notes]
■ If
t2
<
t1
, the OFF time is equal to the ON time.