(*1)”Horizontal size” and “vertical size” indicate the number of dots of the symbol.
(*2)”Other information” indicates whether printing of the data in the symbol storage area is
possible or impossible. The “Other information“ is as following.
Other information
Hex
Decimal
Condition
30H
48
Printing is possible
31H
49
Printing is impossible
■
The decimal value of the vertical size and horizontal size is converted to text data and
sent starting from the high order end.
(ex
: When horizontal size is 120 dots, horizontal size is “120” (in hexadecimal: 31H, 32H, and
30H / in decimal: 49, 50, and 48 ) which is 3 bytes of data.)
■
Size information indicates size of symbol that is printed by Function 181.
■
The quiet zone is not included in the size information.
■
If “other information” is “Printing is impossible“(in decimal: 49) , use one of the solutions
shown below.
Cause
Solution
There are data in the print buffer in the standard
mode
Put the printer in the
“there is no data in the print
buffer” status by executing GS T or print commands
(
LF
,
CR
,
ESC J
).
Symbol is bigger than the current print area.
Expand the print area by
GS W
,
ESC W
,
ESC $
.
Reduce the module size by Function 167.
Lower the error correction level by Function 169.
The data in the symbol area is too large.
Send correct data by Function 180.