6
C
– Electrical requirements
WARNING:
All aspects of the installation must conform to the requirements of the standard North
American wiring rules, as well as your local electrical and building codes and regulations,
as well as any other applicable requirements and conditions of your local power supply
authority. A licensed electrician must perform the electrical work when installing this
appliance. The supply cable and fuse rating must be suitable for the appliance. The range
is supplied with a 40AMP cord.
240Volt 60Hz 40AMP (range with ceramic cooktop)
Note:
To the electrician
– please ensure sufficient supply cable is provided to allow the appliance to be
removed from the cavity should any servicing be necessary. This will also allow for easy
connection to the main power.
Voltage supply connection, if unit not supplied with power cord
To connect the electrical supply:
1- This appliance must be installed on its own separate and distinct final sub-circuit.
2- Ensure the supply cable and fuse rating are suitable for the appliance
3- Remove the cover plate by loosening the screw.
4- Fit a suitable entry bush to the conduit entry on the rear left of the appliance (with the rear
toward you) and feed the fixed wiring through.
5- Connect the wiring to the terminal block using the screw connections provided. Ensure
the wires are properly secured to prevent any high resistance electrical connection.
6- Replace the cover plate making sure that the supply wiring is clear of any metal work and
screws.
7- If the supply cord is damaged, it must be replaced by the manufacturer, the service
agent, or similarly qualified persons in order to avoid hazards.
When connected to a sub circuit protected by a circuit breaker, it is recommended that the circuit
breaker is the same as the total rating of the appliance.
To fully disconnect the power supply, you must unplug the power cord from the wall
receptacle.