31
Normally, the disturbance takes a few seconds. The Ecook includes a filter that will not show
the
“U” unless multiple power disruptions have occurred. The protection takes place, but the “U” is
not shown with just one short disturbance.
Errors / Alarms:
When an error is detected, the whole appliance or the burner/s are switched off, a beep
sounds (only if
one or more burners are active), and all displays show an
‘F’ letter and the error
code alternately.
While in error status, the keys of the corresponding burners are not operative.
Except EEPROM and microcontroller errors, all errors are recoverable. That is, when the cause
of the error disappears, all displays are deactivated and the cooktop returns to normal operation.
Fault/Error
(Visualization Priority Order)
Burner Displays
(fore 0.5 sec./ back
0.5 sec)
Effect in the
appliance
Normal status recovery
Microcontroller fault
F0
App. off
-------
On/Off key emitter fault
FA
App. off
When the fault
disappears
On/Off key receiver fault
FC
App. off
When the fault
disappears
User interface temperature sensor short-
circuit
FE
App. off
When the fault
disappears
User interface temperature sensor open-
circuit
Ft
App. off
When the fault
disappears
User interface over temperature
Fc
App. off
When user interface
temperature < T
EEPROM fault
FH
App. off
-------
Microcontroller A/D converter multiplexer
fault
FJ
App. off
When the fault
disappears
Ambient Light fault
FL
App. off
When satisfactory
ambient lighting is
detected
Microcontroller A/D converter conversion
fault
FU
App. off
When the fault
disappears
Communication fault
F5
Burner/s off
When the fault
disappears
Burner temperature sensor short-circuit
F1
Burner/s off
When the fault
disappears
Summary of Contents for IR60S