background image

14 

DETECTION ADJUSTMENT

 

1.  Install  the  Walk  Through  Metal  Detector  in  a  stable  state  could  achieve  the 
best  detection  results  (Please  refer  to  "Installation  Environment")  Below  are 

steps for telling if the Walk Through Metal Detector is in a steady state:

 

1) 1 minute after start up, the Walk Through Metal Detector gate is under unshaking 
state. 

2) During test, there should be no alarm sound when tester passing the Walk Through 
Metal Detector and not carrying any metal items. 
3) Combined with the above two situation that the Walk Through Metal Detector is in 

a stable state. 
 

2.

 

In order to exclude the influence of small metal objects such as rings, key, belt 

buckle, shoes on the actual metal objects to be detected, please adjust based on 
the following steps: 

1)

 

Take a small metal objects as sample, which is not within the (Walk Through Metal 

Detector) detection boundaries, such as a string of keys. 
2)

 

Set the sensitivity to a higher level, then let test person take the sample & pass by 

the walk through metal detector, and there will be alarming. 

3)  Appropriately  lower  the  sensitivity,  then  take  the  sample  &  pass  by  the  walk 
through  metal  detector  once  again  ,  if  there  is  still  an  alarm  sound,  then  continue 
lowering the sensitivity until there is no alarm sound . 

Notes:   
if there is a certain detection zone needs lower the sensitivity, then only need to adjust 
the relevant detection zone. With the above adjustments,for any metal objects that is 

less than the sample will not alarm, and for the metal objects that are larger than the 
sample all will be accurately detected. 
 

3. Passing Rules. 

1) Draw a waiting line of 50cm away from the front or back of the walk through metal 
detector, so that the people being detected are queued to pass one by one   

2) When passing the walk through metal detector, People being detected needs to place 
the metal objects (such as key, mobile, employee card, cigarettes, coins and so on) on 
the side of the walk through metal detector chute or wooden table, after passing and 

finish with safe inspection ,then take back their personal belongings.

 

Summary of Contents for SmartGuard E-6006

Page 1: ...Electronics and Computer Industry Inc Atat rk Organized Industrial Zone 10024 St No 9 Cigli Izmir TURKEY Tel 90 232 328 1645 pbx Fax 90 232 328 1674 Whatsapp 90 532 498 3402 www smartguard com tr www...

Page 2: ...MENT 3 PERFORMANCE AND FEATURES 4 PARTS 5 INSTALLATION 6 CONTROL PANEL 7 DETECTION ZONES 7 OPERATION 8 PASSWORD MANAGEMENT 13 OPTIONAL FUNCTIONS 13 DETECTION ADJUSTMENT 14 FAQ 15 TECHNICAL PARAMETERS...

Page 3: ...ill have a 1 minute self inspection after power on to achieve the excellent performance 5 The passers must abide by the predefined standby time and alarm time 1 s when checking walking through one by...

Page 4: ...nd display the alarm zone at once if the metal size in human body is more than the predefined metal parameter of weight quantity or shape so that security staff can find the person with prohibited met...

Page 5: ...ference sources and electromagnetic radiation source are not allowed to close the device the recommended distance is 1 2 meters The parameters of the distance are determined by the installation enviro...

Page 6: ...clude the coins keys jewelry belt buckle etc Digital Pulse Technology Digital Signal Processing DSP and filtering system has excellent anti interference ability Password Protection only the correct pa...

Page 7: ...5 PARTS 1 Door Panel 2 Crossbar 3 Integrated Host 4 Alarm zone LED 5 Infrared Sensors 6 Waterproof Foot Cover 7 Power Line Signal line Interface...

Page 8: ...e main box respectively with bolts and nuts locked tightly 3 Make sure the door probe line on the left and right were tightly inserted into the corresponding socket on the motherboard pay attention to...

Page 9: ...of passer and alarm Standby Indication indicator in red when alarming B LED bar Alarm As Figure 1 there are six sets of unique pinpointing LEDs which represent six detection zones from bottom to top 1...

Page 10: ...djust the Frequency Press ENTER confirm the selection In order to avoid signal interference the frequency code of each adjacent device must be different For user convenient operation we have particula...

Page 11: ...will show H xxx means device whole Sensitivity Level is xxx 10 After Zone Sensitivity Level finish adjustment press SELECT will show AP means entered Application Mode adjustment option Press ENTER to...

Page 12: ...setting 5 One more time press ENTER will show A 18 means the device of 18 zones 6 Press SETUP will show d 01 which is alarm duration time 01 means alarm duration of 1 second maximum alarm duration of...

Page 13: ...ready to work 14 The device will automatically display PASS COUNT ALARM COUNT the number of memories is 99999 press RESET can recount 33 Zone Walk Through Metal Detector 1 Long press SELECT 3 seconds...

Page 14: ...pectively 9 Now Left Right side Zone Sensitivity Level finish adjusting press SELECT entering whole Sensitivity Level adjustment will show H xxx means Device whole Sensitivity Level is xxx 10 After al...

Page 15: ...above If forget password press SETUP SELECT to change E0000 into 88888 then press ENTER and display as 00000 press SELECT to enter the number press SETUP to change next number 6 Enter the password to...

Page 16: ...evel then let test person take the sample pass by the walk through metal detector and there will be alarming 3 Appropriately lower the sensitivity then take the sample pass by the walk through metal d...

Page 17: ...shaking If there s wind suggest customer take wind protection measures or replace the installation location 2 After installed the walk through metal detector there is frequently false alarm while test...

Page 18: ...Working Voltage 100 240VAC Power Frequency 50 60Hz Power Consumption 20W Working Temperature 10 45 Dimension MM External Height 2200 External Width 850 Internal Height 2000 Internal Width Standard 71...

Page 19: ...cond Sensitivity 1 18 detection zones 99 Menu Password 12345 33 Zones Walk Through Metal Detector Product Name Walk Through Metal Detector Alarming Time 1 second Sensitivity 1 33 detection zones 99 Me...

Page 20: ...nty card will regard as invalid While purchasing please confirm the warranty card and receipt and make sure all information filled are correct and detailed and send to us for better services 4 If card...

Reviews: