background image

setting. Or if show “E0000”, means password wrong, need input the correct password 
then can go to the next setting. 
 
5. One more time press “ENTER”, will show “A-6”, means the device of 6 zones. 
 
6. Press “SETUP”, will show “d-01”, which is alarm duration time. “01”means alarm 
duration  of  1  second,  maximum  alarm  duration  of  3  seconds.  Press  “SETUP”  can 
adjust to 01, 02, 03 second. 
 
7. Press “SELECT”, entering Zone-Sensitivity-Level adjustment, will show “1-xxx”,   
(“1”means 1st zone, “xxx” means zone sensitivity level.) Press “SETUP” can reduce 
the zone sensitivity level, press “ENTER” can increase the zone sensitivity level. The 
higher the “xxx”figure, the higher the sensitivity! 
e., Adjust to “1-365”, means the 1st zone sensitivity level is 365, the detectable metal 
object would be a coin or a smaller metal object. 
 
8. Again, press “SELECT”in turn, will show “2-xxx”~“6-xxx”, same as the 1st zone 
sensitivity adjustment, you can adjust each zone sensitivity level respectively. 
 
9.  Press“SELECT”,  will  show  “H-xxx”,  means  device  (whole)  Sensitivity-Level  is 
“xxx”. 
 
10. After Zone-Sensitivity-Level finish adjustment, press “SELECT”, will show “AP”, 
means  entered  Application  Mode  adjustment  option.  Press  “ENTER”  to 
Application-Adjustment  mode  and  press  “SETUP”  can  adjust  the  application.  Then 
press “SELECT” to confirm the selection. The higher the application code figure, the 
lower the sensitivity! (For user convenient operation, we have particularly simplified 
the Application to 6 total, which could meet all general markets requirements!) 
 
11,  Press  “SELECT”,  enter  Volume-Level  adjustment,  and  press  “SETUP” 
show“yL-H”,  means  high  volume,  press  “SETUP”again,  show  “yL-L”means  low 
volume.   
 
12.  Press  “SELECT”,  will  show  “Id-xx”,  means  entered  Device  “ID”adjustment 
option, “xx”means the device ID code. (Press “ENTER”for one time can add “1” in 
single  digits,  press  “SETUP”for  one  time  can  add  “1”  in  10-digit.  Press 
“ENTER””SETUP”for more times will add more respectively!) 
 
13.  Press  “SELECT”,  will  show  “A6”.  Press  “ENTER”  then  come  to  “Inspection 
Mode” and device ready to work. 
 
14.  The  device  will  automatically  display  PASS  COUNT  &  ALARM  COUNT,  the 
number of memories is 99999, press “RESET”can recount.   

 

Summary of Contents for SmartGuard E-6006

Page 1: ...Electronics and Computer Industry Inc Atat rk Organized Industrial Zone 10024 St No 9 Cigli Izmir TURKEY Tel 90 232 328 1645 pbx Fax 90 232 328 1674 Whatsapp 90 532 498 3402 www smartguard com tr www...

Page 2: ...MENT 3 PERFORMANCE AND FEATURES 4 PARTS 5 INSTALLATION 6 CONTROL PANEL 7 DETECTION ZONES 7 OPERATION 8 PASSWORD MANAGEMENT 13 OPTIONAL FUNCTIONS 13 DETECTION ADJUSTMENT 14 FAQ 15 TECHNICAL PARAMETERS...

Page 3: ...ill have a 1 minute self inspection after power on to achieve the excellent performance 5 The passers must abide by the predefined standby time and alarm time 1 s when checking walking through one by...

Page 4: ...nd display the alarm zone at once if the metal size in human body is more than the predefined metal parameter of weight quantity or shape so that security staff can find the person with prohibited met...

Page 5: ...ference sources and electromagnetic radiation source are not allowed to close the device the recommended distance is 1 2 meters The parameters of the distance are determined by the installation enviro...

Page 6: ...clude the coins keys jewelry belt buckle etc Digital Pulse Technology Digital Signal Processing DSP and filtering system has excellent anti interference ability Password Protection only the correct pa...

Page 7: ...5 PARTS 1 Door Panel 2 Crossbar 3 Integrated Host 4 Alarm zone LED 5 Infrared Sensors 6 Waterproof Foot Cover 7 Power Line Signal line Interface...

Page 8: ...e main box respectively with bolts and nuts locked tightly 3 Make sure the door probe line on the left and right were tightly inserted into the corresponding socket on the motherboard pay attention to...

Page 9: ...of passer and alarm Standby Indication indicator in red when alarming B LED bar Alarm As Figure 1 there are six sets of unique pinpointing LEDs which represent six detection zones from bottom to top 1...

Page 10: ...djust the Frequency Press ENTER confirm the selection In order to avoid signal interference the frequency code of each adjacent device must be different For user convenient operation we have particula...

Page 11: ...will show H xxx means device whole Sensitivity Level is xxx 10 After Zone Sensitivity Level finish adjustment press SELECT will show AP means entered Application Mode adjustment option Press ENTER to...

Page 12: ...setting 5 One more time press ENTER will show A 18 means the device of 18 zones 6 Press SETUP will show d 01 which is alarm duration time 01 means alarm duration of 1 second maximum alarm duration of...

Page 13: ...ready to work 14 The device will automatically display PASS COUNT ALARM COUNT the number of memories is 99999 press RESET can recount 33 Zone Walk Through Metal Detector 1 Long press SELECT 3 seconds...

Page 14: ...pectively 9 Now Left Right side Zone Sensitivity Level finish adjusting press SELECT entering whole Sensitivity Level adjustment will show H xxx means Device whole Sensitivity Level is xxx 10 After al...

Page 15: ...above If forget password press SETUP SELECT to change E0000 into 88888 then press ENTER and display as 00000 press SELECT to enter the number press SETUP to change next number 6 Enter the password to...

Page 16: ...evel then let test person take the sample pass by the walk through metal detector and there will be alarming 3 Appropriately lower the sensitivity then take the sample pass by the walk through metal d...

Page 17: ...shaking If there s wind suggest customer take wind protection measures or replace the installation location 2 After installed the walk through metal detector there is frequently false alarm while test...

Page 18: ...Working Voltage 100 240VAC Power Frequency 50 60Hz Power Consumption 20W Working Temperature 10 45 Dimension MM External Height 2200 External Width 850 Internal Height 2000 Internal Width Standard 71...

Page 19: ...cond Sensitivity 1 18 detection zones 99 Menu Password 12345 33 Zones Walk Through Metal Detector Product Name Walk Through Metal Detector Alarming Time 1 second Sensitivity 1 33 detection zones 99 Me...

Page 20: ...nty card will regard as invalid While purchasing please confirm the warranty card and receipt and make sure all information filled are correct and detailed and send to us for better services 4 If card...

Reviews: