setting. Or if show “E0000”, means password wrong, need input the correct password
then can go to the next setting.
5. One more time press “ENTER”, will show “A-6”, means the device of 6 zones.
6. Press “SETUP”, will show “d-01”, which is alarm duration time. “01”means alarm
duration of 1 second, maximum alarm duration of 3 seconds. Press “SETUP” can
adjust to 01, 02, 03 second.
7. Press “SELECT”, entering Zone-Sensitivity-Level adjustment, will show “1-xxx”,
(“1”means 1st zone, “xxx” means zone sensitivity level.) Press “SETUP” can reduce
the zone sensitivity level, press “ENTER” can increase the zone sensitivity level. The
higher the “xxx”figure, the higher the sensitivity!
e., Adjust to “1-365”, means the 1st zone sensitivity level is 365, the detectable metal
object would be a coin or a smaller metal object.
8. Again, press “SELECT”in turn, will show “2-xxx”~“6-xxx”, same as the 1st zone
sensitivity adjustment, you can adjust each zone sensitivity level respectively.
9. Press“SELECT”, will show “H-xxx”, means device (whole) Sensitivity-Level is
“xxx”.
10. After Zone-Sensitivity-Level finish adjustment, press “SELECT”, will show “AP”,
means entered Application Mode adjustment option. Press “ENTER” to
Application-Adjustment mode and press “SETUP” can adjust the application. Then
press “SELECT” to confirm the selection. The higher the application code figure, the
lower the sensitivity! (For user convenient operation, we have particularly simplified
the Application to 6 total, which could meet all general markets requirements!)
11, Press “SELECT”, enter Volume-Level adjustment, and press “SETUP”
show“yL-H”, means high volume, press “SETUP”again, show “yL-L”means low
volume.
12. Press “SELECT”, will show “Id-xx”, means entered Device “ID”adjustment
option, “xx”means the device ID code. (Press “ENTER”for one time can add “1” in
single digits, press “SETUP”for one time can add “1” in 10-digit. Press
“ENTER””SETUP”for more times will add more respectively!)
13. Press “SELECT”, will show “A6”. Press “ENTER” then come to “Inspection
Mode” and device ready to work.
14. The device will automatically display PASS COUNT & ALARM COUNT, the
number of memories is 99999, press “RESET”can recount.