INSTALLATION ENVIRONMENT

 

1. Stationary Metallic Items 

When  installing  the  WTMD,  it  should  stay  away  from  the  stationary  or  fixed  bulk 
metal  items  2  meters;  otherwise  it  will  affect  the  sensitivity  and  cause  false  alarm. 
Metal  items  such  as:  aluminum  alloy  /  stainless  steel  doors  and  windows,  with 
reinforced wall, etc. 

 

2. Movable Metallic Items 

The big metal items can be moved, should stay away from the device about 5 meters 
to  avoid  false  alarm.  Especially  install  the  detector  at  factory  gate  or  ground  floor, 
need to pay attention to the effect of rolling gate, iron security doors, elevators and 
cars on the detector. 

 

3. Floor Vibration 

The  floor  should  be  flat  and  fixed,  to  avoid  false  alarm  after  installation  by  the 
movement of people walking or moving and shaking of metal objects.   

 

4. Electromagnetic Radiation And Electromagnetic Interference 

Because  the  device  uses  bilateral  transceiver  technology,  therefore,  any 
electromagnetic  interference  sources  and  electromagnetic  radiation  source  are  not 
allowed to close the device, the recommended distance is 1~2 meters. The parameters 
of  the  distance  are  determined  by  the  installation  environment,  and  different 
installation environments with different parameters. 
The  electromagnetic  interference  sources  and  electromagnetic  radiation  sources  as 
following: 
Electrical  Control  Box,  Radio  Equipment,  Interphone,  Electronic  Computer  And 
Peripheral  Equipment,  Video  Monitor,  High  Power  Motor,  Power  Transformer,  Ac 
Power  Lines,  Thyristor  Control  Circuit  (High  Power  Switching  Power  Supply, 
Inverter Welder), Engine, Motor etc. 

 

5. Side-By-Side Using(more than 2 pieces WTMD) 

When  installing  the  WTMD  side  by  side  more  than  2  pieces,  there will  be a 
certain degree of influence between each WTMD, it is related to the distance and the 
frequency  between  WTMD.  The  distance  between  2  WTMDs  can  not  be  less  than 
50cm.  Specific  distance  parameters  according  to  the  actual  environment  and  the 
selection of the work frequency to adjust. 

 

6.

 

Can not install the device in windy place. It would cause of false alarm if the 

device would slight swing in the wind. 

 
 
 
 

Summary of Contents for SmartGuard E-6006

Page 1: ...Electronics and Computer Industry Inc Atat rk Organized Industrial Zone 10024 St No 9 Cigli Izmir TURKEY Tel 90 232 328 1645 pbx Fax 90 232 328 1674 Whatsapp 90 532 498 3402 www smartguard com tr www...

Page 2: ...MENT 3 PERFORMANCE AND FEATURES 4 PARTS 5 INSTALLATION 6 CONTROL PANEL 7 DETECTION ZONES 7 OPERATION 8 PASSWORD MANAGEMENT 13 OPTIONAL FUNCTIONS 13 DETECTION ADJUSTMENT 14 FAQ 15 TECHNICAL PARAMETERS...

Page 3: ...ill have a 1 minute self inspection after power on to achieve the excellent performance 5 The passers must abide by the predefined standby time and alarm time 1 s when checking walking through one by...

Page 4: ...nd display the alarm zone at once if the metal size in human body is more than the predefined metal parameter of weight quantity or shape so that security staff can find the person with prohibited met...

Page 5: ...ference sources and electromagnetic radiation source are not allowed to close the device the recommended distance is 1 2 meters The parameters of the distance are determined by the installation enviro...

Page 6: ...clude the coins keys jewelry belt buckle etc Digital Pulse Technology Digital Signal Processing DSP and filtering system has excellent anti interference ability Password Protection only the correct pa...

Page 7: ...5 PARTS 1 Door Panel 2 Crossbar 3 Integrated Host 4 Alarm zone LED 5 Infrared Sensors 6 Waterproof Foot Cover 7 Power Line Signal line Interface...

Page 8: ...e main box respectively with bolts and nuts locked tightly 3 Make sure the door probe line on the left and right were tightly inserted into the corresponding socket on the motherboard pay attention to...

Page 9: ...of passer and alarm Standby Indication indicator in red when alarming B LED bar Alarm As Figure 1 there are six sets of unique pinpointing LEDs which represent six detection zones from bottom to top 1...

Page 10: ...djust the Frequency Press ENTER confirm the selection In order to avoid signal interference the frequency code of each adjacent device must be different For user convenient operation we have particula...

Page 11: ...will show H xxx means device whole Sensitivity Level is xxx 10 After Zone Sensitivity Level finish adjustment press SELECT will show AP means entered Application Mode adjustment option Press ENTER to...

Page 12: ...setting 5 One more time press ENTER will show A 18 means the device of 18 zones 6 Press SETUP will show d 01 which is alarm duration time 01 means alarm duration of 1 second maximum alarm duration of...

Page 13: ...ready to work 14 The device will automatically display PASS COUNT ALARM COUNT the number of memories is 99999 press RESET can recount 33 Zone Walk Through Metal Detector 1 Long press SELECT 3 seconds...

Page 14: ...pectively 9 Now Left Right side Zone Sensitivity Level finish adjusting press SELECT entering whole Sensitivity Level adjustment will show H xxx means Device whole Sensitivity Level is xxx 10 After al...

Page 15: ...above If forget password press SETUP SELECT to change E0000 into 88888 then press ENTER and display as 00000 press SELECT to enter the number press SETUP to change next number 6 Enter the password to...

Page 16: ...evel then let test person take the sample pass by the walk through metal detector and there will be alarming 3 Appropriately lower the sensitivity then take the sample pass by the walk through metal d...

Page 17: ...shaking If there s wind suggest customer take wind protection measures or replace the installation location 2 After installed the walk through metal detector there is frequently false alarm while test...

Page 18: ...Working Voltage 100 240VAC Power Frequency 50 60Hz Power Consumption 20W Working Temperature 10 45 Dimension MM External Height 2200 External Width 850 Internal Height 2000 Internal Width Standard 71...

Page 19: ...cond Sensitivity 1 18 detection zones 99 Menu Password 12345 33 Zones Walk Through Metal Detector Product Name Walk Through Metal Detector Alarming Time 1 second Sensitivity 1 33 detection zones 99 Me...

Page 20: ...nty card will regard as invalid While purchasing please confirm the warranty card and receipt and make sure all information filled are correct and detailed and send to us for better services 4 If card...

Reviews: