EW0526A4_en - rev. A 

Oxygen detectors 

 URS40SS 

05/10/2020 

Gas detection systems for industrial environments 

1/4

 

 

 

 

 

 

Sensigas

®

 

Oxygen detectors 

ATEX 

II 3G  Ex nA nC d IIC T6 Gb certified 

 

URS40SS 

 

 

 

 

 

 

 

 

 

Sssssss 

 

 

 
11…14Vdc power supply. 
Electrochemical cell sensor designed for the detection of oxygen (O

2

). 

Up to three alarm thresholds plus sensing element fail. 

LED on sensing element body to indicate operating status. 

Automatic countdown of sensor life. 

 

Use 

The URS40SS detectors are used to detect oxygen excess or deficiency in hazardous 
(classified) areas of industrial environments and thermal power stations. 

An

 oxygen excess

 forms if it leaks in hospitals, laboratories, welding centres and, more 

in general, where oxygen is stored. 

Oxygen deficiency

 is an indirect measurement of the presence of other explosive or 

asphyxiant

 gases that deplete the oxygen in the air. 

URS40SS detectors transmit data from a local bus connected with their Control Unit, 
which acts as the master unit of the gas detection system. 

Operation 

If there is an oxygen leak or an absence of oxygen, the detector compares the measured 
concentration value with the threshold limit setpoints and energises the system relays if 
associate.  

Alarm  information  is  transmitted  to  the  Control  Unit,  which  energises  its  own  internal 
relay  module  (MR0)  and  the  remote  Relay  and  Display  modules  depending  on  the 
associations.

 

Ordering 

To order, simply state the part number: 

URS40SS

For special versions, on request, please contact Customer Service. 

 

 

Summary of Contents for EsiWelma Sensigas URS40SS

Page 1: ...ratories welding centres and more in general where oxygen is stored Oxygen deficiency is an indirect measurement of the presence of other explosive or asphyxiant gases that deplete the oxygen in the air URS40SS detectors transmit data from a local bus connected with their Control Unit which acts as the master unit of the gas detection system Operation If there is an oxygen leak or an absence of ox...

Page 2: ...40 Gas calibration kit See installation and commissioning chapter TUS40 Handheld terminal for service and maintenance See installation and commissioning chapter CRG40 Gas collecting cone See dedicated data sheet PAP40 Powerful jets protection See dedicated data sheet ATEX markings II 3G Ex nA nC d IIC T6 Gb BVI 07 ATEX 0033 20 C TA 50 C Key to marking information Marking in conformity with all app...

Page 3: ...nto account the environmental issue Refer to the following notes for disposal of the product at the end of its working life or when it is replaced for disposal purposes this product is classified as an electric and electronic device do not dispose of it with normal household waste in particular as regards the printed circuit comply with all local laws in force as far as possible reuse basic materi...

Page 4: ... sensor concerned to the supplier installer who in turn will send it back to the manufacturer Sensors may need to be re calibrated using the TUL40 calibration kit and the TUS40 40 handheld terminal which must be connected to the sensor via the communication on the Power supply and BUS connector For the re calibration procedure see the instructions supplied with the handheld terminal Remove power f...

Reviews: