WIRED INFRA-RED BEAM DETECTORS

ADB Range

88

9 10

tamper switch

Relay contact output NO.NC    contact rating AC/DC30V 30mAMax

Model

Alert distance

Number of beams

Detection mode

Optical source

Response time

Alarm output

Power supply

Power consumption

Operation temperature&humidity

Tamper output

Material

Indoor

Outdoor

Optical axis adjustment

H

Optical axis adjustment

V

ADB2 D

0

ADB

D

30

ADB

D

40

ADB

D

60

ADB

D

80

ADB

D

-100

20m

30m

40m

60m

80m

100m

60m

90m

120m

180m

240m

300m

2 beams

2 beams blocked simultaneous

Infrared digital pulse beam

50-240ms   

adjustable without degree

DC13.8

24V   15W

-25

~55

    5%-95%RH

relative humidity

Relay contact output NC    contact rating DC24V 0.5Amax.

180

°

(

±

90

°

P C resin

Net weight

430g

rtransmitter

Gross weight

790g

cable Entry

Wiring terminal

Lens

I.Technical parameters:

II. Part name:

20

°

(

±

10

°

Trouble output

Relay contact output NC    contact rating AC/DC30V 30mAMax

100mA

Housing

Vertical fine-tune knob

88

9 10

Feature:
1.Under bus connection mode: The digital display of RX synchronize with the TX after the RX receive the signal 
from bus.Please Note: Not used on Security Intruder Alarm System.
2.Anti-fog function: when signal strength decrease slowly to 0.8V the detector will active anti-fog alarm ( TBL out
put), when signal decrease to 0.4V, will active alarm. When signal get back to 1.2v cancel alarm.

In the bus mode

13.8V DC,

1   2   3   4   5

1   2   3   4   5

6   7   8   9  1 0

6   7   8   9  1 0

Alarm output N.O/N.C setting

Buzzer ON/OFF  setting

Function 
set mode

Function 
set mode

Free

Free

Power

Power

Alarm

Tamper

Tamper

7

7

8

8

9

9

1

1

2

2

3

3

4

4

5

5

6

6

A

A

B

B

9

Fault

IV.Setting procedure

1

Remove the cover

3

Put the cable through the hole for wiring.

Cable Entry

2

Attach the paper stencil onto the

   location where the equipment is to 
   be mounted,and drill the holes in the
   positions on its mark.

4

Fix the main body onto the wall.

5

Connect the cable to the wire terminal.

RECEIVER

TRANSMITTER

6

DIP switch

Transmitter

Receiver

88

9 10

15mm

88

9 10

Bus

Bus

2

Multi sensors may be used for long-distance
guarding.Please install according to the below
diagram to avoic interference between beams.

Adjustable angle:horizontal

±

90

°

                    
                               vertical

±

10

°

Direct sunlight,
lamplight etc.

Horizontal180

°(±

90

°)

Vertical

±

10

°

III.Precautions for setting:

Impediment presents during setup

The base is unstable

RX

T
X

TX

R
X

RX

T
X

T
X

RX

Guarding d
istance

Beam spead 
diameter

Guarding distance

B

ea

m s

pr

ea

d d

ia

m

et

er

Installation
 height

Style

0.6m
0.7m

1.0m
1.5m
1.8m

2.1m

ADB
ADB-30
ADB-40
ADB-60
ADB-80
ADB-100

-20

20
30m
40m
60m
80m
100m

m

 

 

INSTALLATION

 

INSTRUCTION

 

The Beam can indicate the signal strength on the display: (Useful for alignment) 
Signal strength indicator ON: Set DIP Switch 7 & 8 ON,
Signal strength indicator OFF: Set DIP Switch 7 & 8 OFF,

Internal Buzzer ON: Switch Dip Switch 9 On (Receiver Only)
Internal Buzzer OFF: Switch Dip Switch 9 Off (Receiver Only)

Alarm Output  N.O. Switch Dip Switch 10 On (Receiver Only)
Alarm Output  N.C. Switch Dip Switch 10 Off (Receiver Only)