66
Sensitive S1
Typical causes:
•
S1/S10 switch distorted
No Motor Drive
Typical causes:
•
Motor connector not plugged into One Board
•
VBATT wire (white) not connected to RM
•
No contact from VER to battery (red wire) on strobe board
•
Broken red wire
•
Door switch not in correct position
•
Motor pinion gear binding
•
Motor not seated
•
Motor flex folded over
•
One Board not connected to SOL1 or SOL2
•
Strobe board and S1/S10 not seated
•
RM damaged
•
Encoder wire not seated
Counter Wheel Hangs Up
Note: Counter wheel and mechanism are present, even though exposure
counter display is electronic.
Typical causes:
•
Trim off plastic flash from main frame
•
Bad pack pawl
•
S9, S10 always making
•
Motor flex retainer not seated
•
LED leads too long
•
Remote socket too high
•
Counter spring not seated, or defective
•
Pick damaged
•
Defective timing gear
•
Gear drive cover not seated
•
Brown wire caught in counter wheel