64
No Dark Slide
Typical causes:
•
Motor flex not seated to wireform switch
•
Poor connection to LCD module
•
Red or black wire not seated to strobe (J14-J15)
•
Erect pin missing
•
Wireform switch block distorted
•
Flex not seated to motor
•
Wire broken on wireform switch block
•
Wireform switch block melted
•
S-9 switch distorted at wireform switch block
•
Wire connector from motor flex not connected to One Board
•
Pick spring not seated
•
Door link not making VER switch to battery switch (at wireform switch block)
•
Counter wheel hang up
•
Battery contacts not seated or missing
•
Door latch distorted
•
Shutter not seated
•
No S1 cycle (See No S1 Cycle, Page 4-7)
Incomplete Dark Slide
Typical causes:
•
Locking cap on Ranging Board Burndy connector not closed
•
Poor LCD Module connection at Ranging Board
•
Defective RM