Removing Ranging Board
Note: Be sure to note the position of all wires and wire connectors before you remove
any parts, then return them to their original positions upon reassembly.
1. Remove the top, mid and bottom covers.
2. Disengage the S10/S1 assembly from the spring tab.
3. Disconnect the follwing wire connectors from the One Board Strobe/Exposure
Module Assembly; J7, J6, J4, J5. (See page 4-15 for locations.)
4. Lift the ranging board slightly to free it from the tabs at the bottom-rear of the main
frame and to gain access to connectors J9, J10 and J11 on the ranging board
(Figure 2-5).
Figure 2-5. Ranging board and connectors for J1, J2 and J3
One Board
Strobe/Exposure
Module
Ranging
Board
J1
J2
J3
J9
J10
J11