69
No End of Pack (EOP) Chime
Typical causes:
•
See No Piezo, Page 4-11
•
Deformed wireform switch (EOP not making)
•
Defective FM
•
Counter wheel hang up (See Counter Wheel Hangs Up, Page 4-8)
Incorrect Blade Speed
Typical causes:
•
Flex at SOL 1 folded over shorting itself
•
Opening blade spring not in correct position
•
Shutter blades not free, walking beam inertia, distorted base block
•
Too many blades
•
Dirty blades
Motor doesn’t Run
Typical causes:
•
Wireform switch not making S9 to VER
•
Quintic hung up
•
RM not seated
•
Poor LCD module connection (See Poor LCD Module Connection, Page 4-9)
Film Speed Switch Failure
Typical causes:
•
Distorted wireform switch block
•
Gear drive flex distorted, torn, folded (causing short)
•
Gear drive flex not making with speed switch