
10.31
ELECTRICAL
10
9923523 - 2012
RANGER
RZR 570 Service Manual
© Copyright 2011 Polaris Sales Inc.
Charging Procedure
1. Remove the battery to prevent damage from leaking
or spilled acid during charging.
2. Charge the battery with a ch arging output no la rger
than 1/10 of the battery’s amp/hr rating. Charge as
needed to raise the specific gravity to 1.270 or greater.
3. Install battery in vehicle. Coat threads of battery bolt
with a corrosion resistant dielectric grease.
4. Connect battery cables.
5. After connecting the battery cables, install the cover
on the battery and attach the hold down strap.
6. Install clear battery vent tube from vehicle to battery
vent.
WARNING:
Vent tube must be free from
obstructions and kinks and securely installed. If not,
battery gases co uld accumu late an d ca use an
explosion. Ve nt sho uld be routed away fro m fr ame
and body to prevent contact with e lectrolyte. Avoid
skin contact with electrolyte, as severe burns could
result. If e lectrolyte contacts the veh icle frame,
corrosion will occur.
7. Route cables so they are tucked away in front and
behind battery.
STARTING SYSTEM
Troubleshooting
Starter Motor Does Not Run
• Battery discharged
• Loose or faulty battery cables or corroded
connections (see Voltage Drop Tests)
• Related wiring loose, disconnected, or corroded
• Poor ground connections at battery cable, starter
motor or starter solenoid (see Voltage Drop Tests)
• Faulty key switch
• Faulty starter solenoid or starter motor
• Engine problem - seized or binding (can engine be
rotated easily)
Starter Motor Turns Over Slowly
• Battery discharged
• Excessive circuit resistance - poor connections
(see Voltage Drop Test)
• Engine problem - seized or binding (can engine be
rotated easily)
• Faulty or worn brushes in starter motor
Starter Motor Turns - Engine Does Not Rotate
• Faulty starter drive
• Faulty starter drive gears or starter motor gear
• Faulty flywheel gear or loose flywheel
Voltage Drop Test
The Voltage Drop Test is used to test for bad connections.
When performing the test, you are testing the amount of
voltage drop through the connection. A poor or corroded
connection will appear as a high voltage reading. Voltage
shown on the meter when testing connections should not
exceed 0.1 VDC per connection or component.
To perform the test, place the meter on DC volts and place
the meter leads across the connection to be tested. Refer
to th e volt age dr op te sts o n the starter system in this
chapter.
Dielectric Grease
(PN 2871329)
WARNING
To avoid the possibility of explosion, connect
positive (+) cable first and negative (-) cable last.
Voltage should not exceed
.1 DC volts per connection
Summary of Contents for 2012 RANGER RZR 570
Page 4: ......