1. Important information
This drive unit is compliant with EN 60335-2-103. These instructions are, above all,
designed to meet the requirements of the aforementioned standards, thus ensuring
the safety of people and property.
WARNING
Any use of this product outside the scope of application described in this guide is
prohibited (see the “Scope of application” paragraph in the manual).
The use of any accessories or any components not recommended by Polargos is
prohibited because they could pose a threat to users.
Polargos will not be liable for any damages resulting from failure to follow the
instructions in this guide.
If there are any doubts when installing the drive unit or to obtain additional information,
please visit the website www.polargos.pl.
These instructions may be modi
fi
ed in case of a change to the standards or parameters
of the drive unit.
2. Condition of the gate, for which the drive unit is intended
Before installing the drive unit, please check whether:
• the gate is in good technical condition
• the gate is correctly balanced
• the structures supporting the gate are strong enough to allow the robust mounting
of the drive unit.
• the gate can be opened and closed manually in a correct manner using a force less
than 150 N.
IMPORTANT
Do not pour water onto the drive unit.
Do not install the drive unit where there is a risk of explosion.
3. Electrical installation
DANGER
The installation of the power supply must comply with the standards in force in the
country, where the drive unit is to be installed, and must be carried out by quali
fi
ed
personnel.
DANGER
The electrical system must be designed exclusively for the drive unit and equipped
with a protection, comprising of the following components:
• a fuse or circuit breaker of 10 A;
• and a di
ff
erential-type device (30 mA).
Multipolar disconnection of the power supply is to be provided.
It is recommended to install a lightning conductor (mandatory maximum residual
voltage of 2 kV).
4. Laying conductors
Cables laid underground must be equipped with a protective sheath with a su
ffi
cient
diameter to contain the drive conductor and the wiring accessories.
Low-voltage conductors subject to weather conditions must be at least H07RN-F type.
For the cables not laid underground, use a cable grommet that will withstand the
weight of passing vehicles.
5. Safety instructions regarding assembly
DANGER
Do not connect the drive unit to a power supply (mains, a battery, or a solar set) until
the assembly is complete.
WARNING
Make sure that danger zones (crushing, cutting, trapping) between the driven part
and the surrounding
fi
xed elements related to the opening movement of the driven
part have been eliminated.
WARNING
Changing any element provided in this kit or using any additional element not
recommended in this guide is strictly prohibited.
Monitor the gate opening or closing and keep all people at a safe distance until the