0000100513/050719/C MDB GO | MDB PRO
13
#
Check
OK
6.
Is the rotation direction of the connected extraction
fan correct?
7.
Is the air volume in the extraction system in
accordance with the design specifications?
5
USE
WARNING!
Fire hazard! Do
not
use the product for polishing
applications in combination with grinding, welding or
any other application that generate sparks.
5.1
Control
The way to control the MDB system, depends on the selected
MDB type;
- MDB GO: refer to the
installation and user manual
of the
ControlGo
- MDB PRO: refer to the
installation manual
and the
online
user manual
of the ControlPro
6
MAINTENANCE
WARNING!
Overdue maintenance can cause fire.
6.1
Periodic maintenance
The indicated maintenance intervals can vary depending on
the specific working and ambient conditions. Therefore, we
recommend to thoroughly inspect the complete system once
every year beside the indicated periodic maintenance. For this
purpose contact your supplier.
Component
Action
Frequency:
every X
months
X=3
X=12
Dustbin
*)
Compressed air
regulator (option)
Drain
X
Housing
Make sure that there is no air
leakage
X
Compressed air
system
Make sure that the connection is
correct
X
Make sure that the pressure is
correct (4-5 bar / 60-75 PSI)
X
Make sure that the valves and
membranes are not damaged
X
Filter cartridges
Make sure that the position is
X
Bolts
Make sure all bolts are correctly
tightened
X
*) During use, you must check the level of contents in the
dustbin regularly. The emptying frequency depends on the
intensity of use and will be a matter of experience.
In the initial stage, do a check on the level of contents of the
dust drawer
two times per week
.
6.2
Emptying the dustbin
Personal protective equipment (PPE)
Wear respiratory protection and protective
gloves when you empty the dustbin.
WARNING
Do
not
remove the dustbin while the fan is running.
• Disconnect the compressed air supply.
• Loosen the drain valve (A) to empty the compressed air
tank.
• Tighten the drain valve.
Fig. 6.1
A
Drain valve
• Loosen the quick release clamp.
• Release the lifting pin and lower the dustbin.
• Pull the dustbin forward.
• Seal the disposal sack securely and take it out.
• Place a new disposal sack in the dustbin.
• Install the dustbin in reverse order.
• Dispose of the full sack in accordance with state or local
regulations.
• Connect the compressed air.
6.3
Filter replacement
Replace all filter cartridges at the same time.
Personal protective equipment (PPE)
Wear respiratory protection and protective
gloves when you replace the filter
cartridges.
WARNING
Do
not
replace the filter cartridges while the fan is
running.
To replace the filter cartridges, do the following.
• Disconnect the compressed air.
• Loosen the drain valve (refer to Fig. 6.1A) to empty the
compressed air tank.
• Tighten the drain valve.
• Disconnect the connected control equipment from the
mains.
• Loosen the star knob (F) and disassemble the cover plate
(E), the nut (D) and the metal washer (C).
• Remove (one of) the upper filter cartridge(s)
12
(B) and put
it in the plastic sack in which the replacement filter
cartridge is supplied.
12.
Removing the upper filter cartridges first, keeps the release of dust to a
minimum