background image

0000100513/050719/C MDB GO | MDB PRO 

4

SCALE 1 : 7.5

A

B

C

D

F

G

E

H

SCALE 1 : 7.5

A

B

C

D

F

G

E

H

Fig. 2.1  Main components and elements

2.2 

Operation

The polluted air is extracted through the air inlet module(s). 

The air passes the filter cartridges inside the housing. The 

filtered air leaves the filter system through the outlet 

module(s) and can either be recirculated or exhausted to the 

atmosphere. 

The filter cartridges are cleaned individually from the inside 

out by compressed air pulses. This filter cleaning system is 

called the RamAir™ pulse amplifier. The dust and dirt particles 

are collected in the dustbin.

Deflector plates behind each air inlet module balance the dust 

load on the filter cartridges. They operate as spark arresters at 

the same time. 

2.2.1  Control 

There are two ways to activate the filter cleaning system of 

the MDB and to control the connected fan.

 

- MDB GO: ControlGo | Intelligent control panel for basic fan/

filter control

 

- MDB PRO: ControlPro | Intelligent control panel with HMI 

with extensive feature package for fan/filter control; remote 

access via network

SAFETY

General

The manufacturer does not accept any liability for 

damage to the product or personal injury caused by 

ignoring of the safety instructions in this manual, or 

by negligence during installation, use, maintenance, and repair 

of the product mentioned on the cover of this document and 

any corresponding accessories. 

 

Specific working conditions or used accessories may require 

additional safety instructions. Immediately contact your 

supplier if you detect a potential danger when using the 

product.

The user of the product is always fully responsible for 

observing the local safety instructions and regulations. 

Obey all applicable safety instructions and regulations.

User manual

 

- Everyone working on or with the product, must be familiar 

with the contents of this manual and must strictly observe 

the instructions therein. The management should instruct the 

personnel in accordance with the manual and observe all 

instructions and directions given. 

 

- Do not change the order of the steps to perform.

 

- Always keep the manual with the product. 

Pictograms and instructions on the product (if 

present)

 

- The pictograms, warning and instructions attached to the 

product are part of the safety features. They must not be 

covered or removed and must be present and legible during 

the entire life of the product. 

 

- Immediately replace or repair damaged or illegible 

pictograms, warnings and instructions.

Users

 

- The use of this product is exclusively reserved to authorised, 

trained and qualified users. Temporary personnel and 

personnel in training can only use the product under 

supervision and responsibility of skilled engineers. 

 

- Stay alert and keep your attention to your work. Do not use 

the product when you are under the influence of drugs, 

alcohol or medicine. 

 

- The product is not to be used by children or persons with 

reduced physical, sensory or mental capabilities, or lack of 

experience and knowledge, unless they have been given 

supervision or instruction. 

 

- Children must be supervised not to play with the product.

Intended use

1

The product has been designed exclusively for filtering fumes 

and particles which are released during the most common 

welding and cutting processes. Using the product for other 

purposes is considered contrary to its intended use. The 

manufacturer accepts no liability for any damage or injury 

resulting from such use. The product has been built in 

accordance with state-of-the-art standards and recognised 

safety regulations. Only use this product when in technically 

perfect condition in accordance with its intended use and the 

instructions explained in the user manual.

Technical specifications

Do not change the specifications given in this manual. 

1.

  “Intended use” as explained in EN-ISO 12100-1 is the use for which the 

technical product is suited as specified by the manufacturer, inclusive of his 

directions in the sales brochure. In case of doubt it is the use which can be 

deduced from the construction, the model and the function of the technical 

product which is considered normal use. Operating the machine within the 

limits of its intended use also involves observing the instructions in the user 

manual.

Summary of Contents for MDB GO

Page 1: ...www plymovent com Central filter system modular MDB GO MDB PRO Installation and user manual EN...

Page 2: ...uideline for installation use maintenance and repair of the product mentioned on the cover page of this document This publication is to be used for the standard model of the product of the type given...

Page 3: ...iDust Bank equals to MDB The specific product type 4 6 8 etc corresponds with the number of filter cartridges Suffixes H horizontal layout V vertical layout no suffix square layout 1 INTRODUCTION 1 1...

Page 4: ...to ISO 8573 3 class 6 Required pressure 4 5 bar 60 75 PSI Compressed air connection push in fitting in in out 12 mm Compressed air consumption 40 50 nl pulse 1 4 1 8 ft pulse Electrical data Input vol...

Page 5: ...uctions and directions given Do not change the order of the steps to perform Always keep the manual with the product Pictograms and instructions on the product if present The pictograms warning and in...

Page 6: ...s for persons who enter the work area Check the working environment Do not allow unauthorised persons to enter the working environment Protect the product against water and humidity Make sure the room...

Page 7: ...V on page 18 B Air outlet module MDB OUTLET Fig 4 4 Drill a 9 mm 0 25 in hole in the two notches A of the outlet module Fig 4 2 A 2x Air outlet module 2 Note the open sides of the bars are on the outs...

Page 8: ...g the sticky side with your fingers Make sure that you attach the seal in the centre of the frame edges and that the jigsaws fit together Peel approx 50 mm of the backing material A and stick the seal...

Page 9: ...rry about a slight misalignment of the seal holes Fig 4 14 Start with a long seal 1046 mm Try to avoid touching the sticky side with your fingers Make sure that you attach the seal in the centre of th...

Page 10: ...e Fig 4 16 Put the MDB FRAME A in fully horizontal position 8 The seals are extremely adhesive without the use of SealApplicator components might stick together in the wrong position and cannot be dis...

Page 11: ...lter modules and tighten them with a flange nut B Fig 4 22 A A A A B B B B B A 4x B 5x Position of studs Fig 4 23 Multiple stack MDB system only 1 Remove the backing material of the seals horizontal v...

Page 12: ...an end cap When you install ducting at both sides of the modules you do not need to install an end cap If applicable Put an end cap on the open side of the air inlet outlet module Fasten it with self...

Page 13: ...hopper with the quick connect clamp B Fig 4 29 A B C D Dustbin 4 10 Electric connection For the electric connection of the filter cleaning system and the fan refer to the installation manual of the c...

Page 14: ...s in the dustbin regularly The emptying frequency depends on the intensity of use and will be a matter of experience In the initial stage do a check on the level of contents of the dust drawer two tim...

Page 15: ...cartridges Inverted direction of rotation of the motor of the connected fan Change the direction of rotation Pollution of the facility Filter cartridge s ripped or placed incorrectly Replace the filt...

Page 16: ...s of the following Directives Machine Directive 2006 42 EC EMC 2014 30 EU LVD 2014 35 EU ErP Directive 2009 125 EC Alkmaar Netherlands 1 July 2019 M S J Ligthart Product Manager An installation is def...

Page 17: ...51 5 5 15 7 5 20 PTFE 15 180 1938 5400 14400 3178 8476 MDB 16 16 PTFE 10 160 1722 4800 12800 2825 7534 5 5 18 5 7 5 25 PTFE 15 240 2583 7200 19200 4238 11301 MDB 18 18 PTFE 10 180 1938 5400 14400 3178...

Page 18: ...4x 18x 2x 22x 26x 22x 11x MDB COVER 2 4x 18x 2x 22x 26x 22x 11x MDB COVER U 4x 18x 2x 22x 26x 22x 11x MDB INLET 315 MDB INLET 400 MDB INLET 500 4x 18x 2x 22x 26x 22x 11x MDB OUTLET 315 MDB OUTLET 400...

Page 19: ...uence of MDB system if applicable install the MDB BM 2 module s first layer by layer from left to right one filter module at a time 1 2 3 1 2 3 4 5 6 1 2 3 2 4 6 Fig V Inlet and outlet positions Possi...

Page 20: ...lve inch 0000102584 Lock kit for CART filter cartridge 0000102598 Star knob M12 0000102666 Cover plate for filter cartridge CART 0000102675 Filter cartridge holder Article no Description 0000103150 Ma...

Page 21: ...www plymovent com 0000100513 050719 C MDB GO MDB PRO...

Reviews: