background image

0000100513/050719/C MDB GO | MDB PRO 

7

Fig. 4.6 

Dustbin lift

•  Install the dustbin lift (B) to the frame. Put the bolts 

M10x40 (A) from the inside into the slotted holes

3

Fig. 4.6 

D

A

A

B

A

B

C

A

Dustbin lift

Fig. 4.7

•  Install the locking device (A) with 2 washers and 2 bolts. 

Fig. 4.7 

D

A

A

B

A

B

C

A

Locking device

Fig. 4.8

•  Put the lifting pin (B) through the holes and attach it with 2 

cotter pins (A). 

•  Put the extension pin with handle (C) into the lifting pin. 

Fig. 4.8 

D

A

A

B

A

B

C

A

Lifting pin

Fig. 4.9

Sealing (MDB seal assembly set)

How to apply the seals: How to use SealApplicator:

•  Remove dust, if any, from the upper frame. 

•  Lay the seals loosely on the frame and put them together

4

.

•  Make sure that the jigsaws tightly fit.

3.

  No nuts involved. The dustbin lift has some tolerance

4.

  Do not worry about a slight misalignment of the seal holes

Fig. 4.9  Seals on frame

One strip 846 mm (33.3 in.) is redundant.

Fig. 4.10

•  Start with a 

long

 seal (1046 mm). 

•  Try to avoid touching the sticky side with your 

fingers.

•  Make sure that you attach the seal in the 

centre

 

of the frame edges and that the jigsaws fit 

together.

•  Peel approx. 50 mm of the backing material (A) and stick 

the seal on the frame. Draw the backing material to the 

inside

 of the frame. 

•  Continue to peel and stick the seal in steps of approx. 50 

mm according to the indicated sequence (B).

Fig. 4.10 

A

B

± 50 mm

1

2

3

4

5

Removal of backing material

4.4 

Filter modules (MDB-BM/2 and/or 

MDB-BM/4)

MDB filter systems often consist of more than one filter 

module. You must assemble the system layer by layer from 

left to right. 

Fig. IV on page 18 shows an example of the 

correct sequence. 

If applicable: install the MDB-BM/2 module(s) first.

Specially constructed seals (MDB seal assembly set) between 

the frame, the individual filter modules, the air inlet/outlet 

modules and the cover plates are necessary to make the entire 

MDB system airtight. The top and right side of each filter 

module are already provided with seals. Only the filter 

modules on the 

left

 side of the MDB system must be provided 

with additional seals. The number depends on the system 

configuration. 

Summary of Contents for MDB GO

Page 1: ...www plymovent com Central filter system modular MDB GO MDB PRO Installation and user manual EN...

Page 2: ...uideline for installation use maintenance and repair of the product mentioned on the cover page of this document This publication is to be used for the standard model of the product of the type given...

Page 3: ...iDust Bank equals to MDB The specific product type 4 6 8 etc corresponds with the number of filter cartridges Suffixes H horizontal layout V vertical layout no suffix square layout 1 INTRODUCTION 1 1...

Page 4: ...to ISO 8573 3 class 6 Required pressure 4 5 bar 60 75 PSI Compressed air connection push in fitting in in out 12 mm Compressed air consumption 40 50 nl pulse 1 4 1 8 ft pulse Electrical data Input vol...

Page 5: ...uctions and directions given Do not change the order of the steps to perform Always keep the manual with the product Pictograms and instructions on the product if present The pictograms warning and in...

Page 6: ...s for persons who enter the work area Check the working environment Do not allow unauthorised persons to enter the working environment Protect the product against water and humidity Make sure the room...

Page 7: ...V on page 18 B Air outlet module MDB OUTLET Fig 4 4 Drill a 9 mm 0 25 in hole in the two notches A of the outlet module Fig 4 2 A 2x Air outlet module 2 Note the open sides of the bars are on the outs...

Page 8: ...g the sticky side with your fingers Make sure that you attach the seal in the centre of the frame edges and that the jigsaws fit together Peel approx 50 mm of the backing material A and stick the seal...

Page 9: ...rry about a slight misalignment of the seal holes Fig 4 14 Start with a long seal 1046 mm Try to avoid touching the sticky side with your fingers Make sure that you attach the seal in the centre of th...

Page 10: ...e Fig 4 16 Put the MDB FRAME A in fully horizontal position 8 The seals are extremely adhesive without the use of SealApplicator components might stick together in the wrong position and cannot be dis...

Page 11: ...lter modules and tighten them with a flange nut B Fig 4 22 A A A A B B B B B A 4x B 5x Position of studs Fig 4 23 Multiple stack MDB system only 1 Remove the backing material of the seals horizontal v...

Page 12: ...an end cap When you install ducting at both sides of the modules you do not need to install an end cap If applicable Put an end cap on the open side of the air inlet outlet module Fasten it with self...

Page 13: ...hopper with the quick connect clamp B Fig 4 29 A B C D Dustbin 4 10 Electric connection For the electric connection of the filter cleaning system and the fan refer to the installation manual of the c...

Page 14: ...s in the dustbin regularly The emptying frequency depends on the intensity of use and will be a matter of experience In the initial stage do a check on the level of contents of the dust drawer two tim...

Page 15: ...cartridges Inverted direction of rotation of the motor of the connected fan Change the direction of rotation Pollution of the facility Filter cartridge s ripped or placed incorrectly Replace the filt...

Page 16: ...s of the following Directives Machine Directive 2006 42 EC EMC 2014 30 EU LVD 2014 35 EU ErP Directive 2009 125 EC Alkmaar Netherlands 1 July 2019 M S J Ligthart Product Manager An installation is def...

Page 17: ...51 5 5 15 7 5 20 PTFE 15 180 1938 5400 14400 3178 8476 MDB 16 16 PTFE 10 160 1722 4800 12800 2825 7534 5 5 18 5 7 5 25 PTFE 15 240 2583 7200 19200 4238 11301 MDB 18 18 PTFE 10 180 1938 5400 14400 3178...

Page 18: ...4x 18x 2x 22x 26x 22x 11x MDB COVER 2 4x 18x 2x 22x 26x 22x 11x MDB COVER U 4x 18x 2x 22x 26x 22x 11x MDB INLET 315 MDB INLET 400 MDB INLET 500 4x 18x 2x 22x 26x 22x 11x MDB OUTLET 315 MDB OUTLET 400...

Page 19: ...uence of MDB system if applicable install the MDB BM 2 module s first layer by layer from left to right one filter module at a time 1 2 3 1 2 3 4 5 6 1 2 3 2 4 6 Fig V Inlet and outlet positions Possi...

Page 20: ...lve inch 0000102584 Lock kit for CART filter cartridge 0000102598 Star knob M12 0000102666 Cover plate for filter cartridge CART 0000102675 Filter cartridge holder Article no Description 0000103150 Ma...

Page 21: ...www plymovent com 0000100513 050719 C MDB GO MDB PRO...

Reviews: