12.1 Trouble shooting
Trouble Shooting
Problem
Fault
Solution
Lift not operating
Circuit breaker or fuse tripped
Reset circuit breaker or replace fuse
Cab switch not turned on
Turn cab switch on
Door switch sticking
Lubricate and free switch
Low voltage
Charge battery
Poor earth
Check battery cables & earth points
Corrosion on crimped cables
Re-crimp cables and clean corrosion
Loose power-pack electrical connections
Check electrical connections
Handset failure
Replace handset
Lift stuck in box
Box lock not fully disengaged
Make sure lock handle is pulled fully up
Lift is pressurized up in box
Press Down on handset to lower lift or
open the down valve to release
pressure
Box grounded and damaged underneath
Repair / replace box
Lift not powering IN
Motor cut-off switch (In switch)
Check switch adjustment & lubricate
Umbilical damaged
Replace umbilical cable
Carriage solenoid failure
Replace solenoid
Motor failure
Replace motor
Carriage lock not lowering correctly
Check & readjust carriage lock stowing
Carriage lock switch failure
Check switch adjustment & lubricate
Lift not powering OUT
Lift Up switch (Out switch)
Check switch adjustment & lubricate
Umbilical damaged
Replace umbilical cable
Carriage solenoid failure
Replace solenoid
Motor failure
Replace motor
Loose carriage electrical connections
Check plugs, sockets & pins
Lift not powering UP
Low oil
Add PLS Blue Hydraulic oil
No pump pressure
Check and readjust pressure relief
Hose burst
Replace
Lift Up switch (Out switch)
Check switch adjustment & lubricate
Manual release left open
Close manual override
Down valve stuck open (contamination)
Remove / clean and replace
Low voltage
Charge battery
Lift not lowering DOWN
Contamination in PC Burst valves
Replace PC burst valve set
Crash vales locked (cold weather)
Readjust crash valve gap
Down valve not opening due to low voltage Charge battery
Down valve sticking (contamination)
Remove / clean and replace
Down valve coil failure
Check / replace
Problem
Fault
Solution
Platform Extension will not
extend
Handrails not raised up
Raise up handrails into locked position
12
TROUBLESHOOTING
12.1 Troubleshooting Instructions
Summary of Contents for Access ACC-1150
Page 7: ...1 1 5 Heath Safety Scooters General ...
Page 23: ...7 7 7 Floor Height Adjustment Installation 7 INSTALLATION 7 6 Floor Height Adjustment ...
Page 25: ...7 7 9 Weight Test Installation 7 INSTALLATION 7 8 Weight Test Dynamic Dynamic ...
Page 30: ...Thread Size Tightening Torque Nm Hydraulic Fitting BSP 1 8 17 0 1 4 34 0 3 8 47 0 ...
Page 31: ...8 8 1 Standard Operating Procedure Operation 8 OPERATION 8 1 Standard Operating Procedure ...
Page 32: ...8 8 2 Manual Override Procedure Operation 8 OPERATION 8 2 Manual Override Procedure ...
Page 35: ...10 10 2 Loler Service Maintenance ...
Page 44: ...13 13 1 Wiring Diagram Power Pack Diagrams 13 DIAGRAMS 13 1 Wiring Diagram Power Pack ...
Page 46: ...13 13 3 Hydraulic Diagram Diagrams 13 DIAGRAMS 13 3 Hydraulic Diagram ...
Page 82: ...15 Notes ...
Page 83: ...15 Notes ...