CIP Training
Plockmatic LCT3500 Large Capacity Tray
Basics
Loading Paper
6
6
The Vacuum Size Valve controls the size
of the vacuum suction area on the bottom
of the vacuum chamber. The Vacuum Size
Valve needs to be manually shifted to the
correct position, which depends on paper
width. If paper width is greater than 188
mm, the lever needs to be positioned as
shown. If paper width is less than 188 mm,
the lever needs to be shifted to the
corresponding position (<188 mm/7.4”);
7
7
Close tray and repeat procedure on the
other tray if required
.
NOTE: if you are not using the Paper Supports, place them in the Paper Support
Holders
[G]