background image

Copyright Planika Sp. z o.o.  

www.planikafires.com 

 

IG0098#01 

19.02.2018 

 

17 

Gas cylinder connection 

Twist-on connection 

Quick-release 

1.

 

Check if the bottle valve is TURNED OFF turning 
it clockwise 

2.

 

Remove the protection tip and store it for later 
use. 

1.

 

Remove the protection tip. Do not use any tools, 
leave the tip hanging freely.

 

3.

 

Before making the connection check if the black 
seal is not damaged. 

 

2.

 

Make  sure  all  the  taps  on  the  gas  device  are 
closed and if the switch in in the OFF position. 

 

4.

 

Fit  the  connecting  nut  to  the  cylinder  with  the 
use of a correct wrench or the connecting knob. 
(left  thread)  Do  not  allow  the  gas  cylinder 
connectors to be fastened too tightly. 

 

3.

 

Place  the  quick-release  regulator  on  the  valve 
and press it down hard. If the switch is correctly 
turned off you will hear a characteristic click. 

 

5.

 

When the gas flow is required turn the valve of 
the bottle counter-clockwise. 

 

4.

 

To let the gas flow in turn the switch into the ON 
position (or into the flame image). 

 

 

Place the gas cylinder in a correct distance from the fireplace (min 1,5 metres away).  

 

WARNING!!!

 

Check the gas connection for leakage. If anything suggests a leak is present (for instance a 

characteristic gas smell) close the gas cylinder valve and under no circumstances turn the device on before 

removing the leak.

 

 

After removing the leak one may open the gas cylinder valve again. 

 

Summary of Contents for GaLiO Insert #2

Page 1: ...01 19 02 2018 1 INSTALLATION MANUAL GaLiO Insert 2 G20 G25 Natural Gas G30 G31 Propane Butane Propane Manufactured by Planika Sp z o o Bydgoska 38 86 061 Brzoza Poland H H1 H2 H3 L L1 L2 L3 L4 D D1 D2 mm 260 258 5 1 5 120 1027 944 43 5 43 5 240 230 205 160 ...

Page 2: ...t 8 4 1 2 Montage involving use of adjustable supports 9 4 2 Control panel and gas cylinder montage 11 4 3 Possible housing variants 15 4 3 1 Situations in which montage of glass screen protection is mandatory 15 4 3 2 Situations in which the glass screen montage is forbidden 15 5 INSTALLATION OF THE GAS LINKAGE 16 5 1 Natural gas connection 16 5 2 Connection and replacement of the gas cylinder LP...

Page 3: ...threat of damaging the unit or causing a fire A CO2 or a powder fire extinguisher needs to be placed near the device During the first ignition the GaLiO Insert fireplace needs to be burnt on maximum level for a few hours in order for the elements to acquire correct temperature and for the remains of paint lacquer and lubricant to evaporate Do not move the device while it s working The GaLiO Insert...

Page 4: ... linkage every 2 years The elastic linkage connecting gas to the fireplace is to be led away from sharp edges and hot surfaces Refrain from bends and twists of the elastic connection on its full length Remember that the LPG bottle should be stored in a well ventilated place LPG gas is heavier than air and its accumulation near the surface may generate an explosive mixture The housing in which the ...

Page 5: ...tify the supplier Install the GaLiO Insert fireplace in the prepared housing made according to the montage specification The decorative stones are to be scattered evenly around the reservoir to completely cover the burner of the fireplace WARNING The stones may not cover or be placed inside the device protecting the ignition unit Photo 1 Photo 1 In the case of GaLiO Insert powered with natural gas...

Page 6: ...bjects in direct contact with the device nor within a 1 metre radius from the fire Additionally Planika doesn t recommend placing heat sensitive objects above the fireplace as it may shorten their lifetime Planika will not be responsible for any damage caused by high temperature affecting objects installed above the fire Non flammable materials Ventilation grate or slot with ventilation area of mi...

Page 7: ...wings and a ventilation grid or slot with ventilation area min 150cm2 needs to be placed near the base of the unit minimally 110 mm below the burner surface If a hood is placed above the burner it needs to be made of non flammable materials and a minimum distance of 60 cm from the surface of the burner needs to be observed WARNING If the housing is devoid of a diagonal hood above the burner one ne...

Page 8: ...on variant Make the cavity for the insert according to the below outline When preparing the cavity make sure the surface on which the insert is placed is well levelled as there is no option of levelling out the insert Ventilation grate or slot with ventilation area of minimum 150cm2 Ventilation grate or slot with ventilation area of minimum 150cm2 ...

Page 9: ... a fire 4 1 2 Montage involving use of adjustable supports In this montage variant the insert is using the help of supports attached to the device An appropriate space needs to be provided around the fireplace allowing its trouble free installation and providing correct circulation inside the fireplace Level the plane of the cavity The level deviation must not exceed 2 mm Ventilation grate or slot...

Page 10: ...he insert is to be placed need to be finished in an aesthetic way as they will be visible during normal use of the device In case of the cavity being deeper than the height of the device on supports Planika permits a solution where the device is set on a stable and levelled plinth placed on the bottom of the cavity The top surface of the plinth should be H 10 mm away from the top of the surface of...

Page 11: ...use incorrect operation of the device and in a worst case scenario a fire 4 2 Control panel and gas cylinder montage 4 2 1 Montage of the gas cylinder The control panel along with the gas valve is inseparably connected with the GaLiO Insert fireplace through elastic gas linkage and the ignition linkage Level the plane of the cavity The level deviation must not exceed 2 mm ...

Page 12: ... crucial to manufacture a slot in the side of the housing where the insert is placed for the gas linkage and the pressure regulator only in case of LPG version The gas linkage attached to the device allows to place the gas cylinder maximally 3 metres away from the connected control panel however it cannot be placed nearer to the device than 1 5 metres ...

Page 13: ...linders however they also have to be sufficient for hassle free installation of the gas cylinder 4 2 2 Control panel montage in a separate storage The control panel along with the gas valve connected with the insert through elastic linkage may be installed away from the housing for the GaLiO Insert It can be placed maximally within a 1 metre radius from the centre of the device Before placing the ...

Page 14: ...ay vary to accommodate different types and dimensions of the gas cylinders however they also have to be sufficient for hassle free installation of the gas cylinder Control panel montage above the gas cylinder is not recommended as it would impede its hassle free installation and replacement WARNING After making sure that the device has been correctly installed acquaint yourself with the attached U...

Page 15: ... glass screen protection is mandatory 4 3 2 Situations in which the glass screen montage is forbidden The montage of toughened glass screen panels is advised and recommended on both sides of the fireplace in this case or leaving those sides without the montage of the glass screen In this case one has to put an emphasis on safety measures and disallow children unauthorised persons and animals to ha...

Page 16: ...mensions so there is no pressure loss Ball gas valve should be installed in an easily accessible place and have the necessary CE mark 5 2 Connection and replacement of the gas cylinder LPG version The GaLiO Insert is delivered together with an elastic gas linkage which on one end is connected to the valve of the device and on the other end to the 37mbar regulator in the twist on version ready to b...

Page 17: ...ecting knob left thread Do not allow the gas cylinder connectors to be fastened too tightly 3 Place the quick release regulator on the valve and press it down hard If the switch is correctly turned off you will hear a characteristic click 5 When the gas flow is required turn the valve of the bottle counter clockwise 4 To let the gas flow in turn the switch into the ON position or into the flame im...

Page 18: ...egulator or the connecting nut with the use of a wrench or a connecting knob 3 Take off the quick release regulator by pressing the switch horizontally and simultaneously pulling the whole regulator upwards 5 REPLACE the linkage closer or cap on the empty or partially full bottle if it s not being used 4 REPLACE the tightening cap on an empty or partially full bottle if it s not being used 5 3 Ada...

Page 19: ... 4 Pressure regulator replacement LPG version 1 You always need to use a pressure regulator between the gas cylinder and the device Replace the pressure regulator every 5 years Allowed pressures 30 mbar 37 mbar recommended 50 mbar Use only the redactors that comply with the EN16129 European Norm 2 Turn off the GaLiO Insert the OFF position The main burner and the pilot burner need to be turned off...

Page 20: ...I3P 50 I2E 20 I2H 20 Device type A1 Outdoor A1 Outdoor A1 Outdoor A1 Outdoor Reference gas G30 G31 G30 G31 G30 G31 G20 Net input Hi kW 10 3 11 8 12 9 9 4 Input pressure mbar 30 37 50 20 Gas flow at 15 C and 1013 mbar m3 h 1 0 Gas flow at 15 C and 1013 mbar kg h 0 81 0 93 1 02 Burner pressure at max flame height mbar 22 2 27 3 35 4 11 0 Nozzle of the main burner mm 2 2 2 2 2 2 2 7 Pilot unit G30 ZP...

Page 21: ...Planika Sp z o o www planikafires com IG0098 01 19 02 2018 21 7 MANUFACTURER S CONTACT DETAILS Manufacturer Planika Sp z o o Address Bydgoska 38 86 061 Brzoza Poland Telephone 48 52 364 11 60 Fax 48 52 364 11 70 ...

Reviews: