Copyright Planika Sp. z o.o.
www.planikafires.com
IG0098#01
19.02.2018
20
7.
Attach a new linkage on the stub of
regulator.
8.
Move the clamp into the stub again and
tighten it. WARNING! In the event of
visible damage on the clamp, replace it
for a new one.
6.
TECHNICAL SPECIFICATION
Gas category
I3B/P(30); I3P(30);
I3+(28-30/37)
I3B/P(37);
I3P(37);
I3B/P(50);
I3P(50);
I2E(20);
I2H(20);
Device type
A1 Outdoor
A1 Outdoor
A1 Outdoor
A1 Outdoor
Reference gas
G30/G31
G30/G31
G30/G31
G20
Net input (Hi)
kW
10,3
11,8
12,9
9,4
Input pressure
mbar
30
37
50
20
Gas flow at 15°C
and 1013 mbar
m
3
/h
-----
-----
-----
1,0
Gas flow at 15°C
and 1013 mbar
kg/h
0,81
0,93
1,02
-----
Burner pressure at max
flame height
mbar
22,2
27,3
35,4
11,0
Nozzle of the main burner
mm
2,2
2,2
2,2
2,7
Pilot unit
G30-ZP2M-L
G30-ZP2M-L
G30-ZP2M-L
G30-ZP2M-L
Gas control valve
Mertik GV 60
Mertik GV 60
Mertik GV 60 Mertik GV 60
Gas linkage
Ø9mm
Ø9mm
Ø9mm
External ⅜”